Comparison Zubr D2-40 vs Zubr D40t

Add to comparison
Zubr D2-40
Zubr D40t
Zubr D2-40Zubr D40t
Outdated ProductOutdated Product
TOP sellers
Devicevoltage Monitoring Relaysvoltage Monitoring Relays
Voltagevariablevariable
Number of phases11
MountdIN raildIN rail
Width (unit)2 U3 U
Specs
Power8.8 kVA8.8 kVA
Rated current40 А40 А
Maximum current50 А50 А
Voltage measuring range100 – 420 V100 – 400 V
Cut-off time (lower limit)0.04 с1.2 с
Off time (upper limit)0.04 с0.04 с
Reclosing delay3 – 600 с3 – 600 с
Lower cut-off limit120 – 210 V120 – 210 V
Upper cut-off limit220 – 280 V220 – 280 V
Functions
display
operation indicator
thermal protection
fault memory
display
operation indicator
thermal protection
fault memory
General
Adjustmentdigitaldigital
Protection levelIP20IP20
Dimensions66x85x36 mm70x85x53 mm
Weight170 g210 g
Added to E-Catalogfebruary 2019december 2017

Width (unit)

Width expressed in unit units. This unit is used to measure the width of rack-mounted devices and makes it easy to estimate how much space you need. Width in unit is always expressed as whole numbers, 1 unit is approximately equal to 17.5 mm. There are models 1U, 2U, 3U and more

Voltage measuring range

Voltage measurement range supported by the device.

Many modern control relays are equipped with digital displays, which can display, including current voltage; this parameter specifies the operating range of the built-in voltmeter. In this case, the voltage measurement range can be noticeably wider than the difference between the smallest minimum and the largest maximum shutdown threshold (see below). This allows you to use the relay also for online diagnostics of the network status.

For a current relay (see "Device") in this case, the range of operating voltages can be given directly — the voltage at which the device can normally perform its functions.

Cut-off time (lower limit)

Time to turn off the device on the lower limit of voltage or current. This is a kind of "reaction time" of the relay: the period of time between reaching the lower limit and turning off the protected network segment.

The lower this value, the more advanced the protection will be, the lower the probability of failure of sensitive devices due to untimely operation of the relay. On the other hand, a high response rate for the lower limit is not as critical as for the upper one, and the shutdown time can be quite long — 1 s or more.

Also note that for some devices, this paragraph gives the minimum turn-off time (fastest response time), while in certain modes this time may be longer. For example, a voltage relay with a lower limit of 160 V may provide tripping after less than 0.05 s when the voltage drops below 120 V and tripping after 1 s when the voltage is in the range of 120 – 160 V, but above 120 V. This avoids unnecessary shutdowns with relatively weak and short-term voltage deviations. In the characteristics of such a device, 0.05 s will be indicated.