Dark mode
United Kingdom
Catalog   /   Tools & Gardening   /   Measuring tools   /   Pyrometers

Comparison Benetech GM300 vs UNI-T UT300C

Add to comparison
Benetech GM300
UNI-T UT300C
Benetech GM300UNI-T UT300C
Outdated ProductOutdated Product
TOP sellers
Designgungun
Target designatorsingle pointsingle point
Specs
Surface t measurements-50 – 420 °C-20 – 400 °C
Distance to spot ratio1212
Response time500 ms500 ms
Measurement accuracy1.5 °C2 °C
Measurement accuracy1.5 %2 %
Operating temperature0 – 40 °C0 – 40 °C
Functions
 
emissivity adjustment
General
Power sourcePP3PP3
Dimensions153x101x43 mm153x108x40 mm
Weight147 g185 g
Added to E-Catalogmarch 2018march 2018

Surface t measurements

The range of surface temperatures that the instrument can effectively measure.

In general, the meaning of this parameter is quite obvious. We only note that an extensive operating range is not always an advantage. First, it affects the cost of the device; secondly, when the range is extended, the measurement accuracy may deteriorate. So when choosing, you should not chase the maximum temperature range, but take into account real needs: for example, it hardly makes sense to choose a pyrometer with an upper limit of 500 °C for measuring the quality of thermal insulation and determining heat leaks in residential premises. It is conditionally possible to divide pyrometers into those that are for measuring low temperatures, and, accordingly, for high ones.

Measurement accuracy

Temperature measurement accuracy provided by the pyrometer, in degrees. It is indicated by the maximum deviation in one direction or another, which the device can give out during operation. For example, if the specification says 1.5°C and the reading reads 80°C, the actual temperature could be between 78.5°C and 81.5°C. Thus, the smaller the number in this paragraph, the lower the error and the higher the accuracy of the device. At the same time, high accuracy has a corresponding effect on cost.

It should be noted that this designation often turns out to be very conditional, and the detailed characteristics may contain various clarifications regarding errors. So, the accuracy of measurements is often given simultaneously in degrees and in percentages with a wording like "± 2 °C or ± 2%, whichever value is greater." For details on percentage error, see Measurement Accuracy below. And this record means that the actual measurement error in degrees may turn out to be even higher than that directly stated in the characteristics — for example, 2% of 500 °C gives a deviation of ± 10 °C. In addition, there may be other refinements — for example, at sub-zero temperatures, the deviation can be ± 2 °C plus 0.05 °C for each degree below zero (that is, increase with decreasing temperature). So if high measurement accuracy is critical for you, you should carefully read the manufacturer's documentation.

Measurement accuracy

The accuracy of temperature measurements provided by the pyrometer, in percent. It is indicated by the maximum deviation in one direction or another, which the device can give out during operation. The percentage is taken from the actual temperature value; In fact, this means that the greater the deviation from zero, the higher the error can be. For example, at 100 °C an error of 2% gives a deviation of ±2 °C, and at 500 °C this value already reaches ±10 °C. However, this does not mean that when approaching zero, the error disappears — for this case, the measurement accuracy in degrees is given in parallel in the characteristics (see above). In this case, wordings like “± 2 °C or ± 2%, which of the values will be greater” are used; at low temperatures, when the percentage error will be unrealistically small (for example, for 20 °C, the same 2% will give only ± 0.4 °C), it is worth evaluating the accuracy of measurements by the error in degrees.

Functions

Adjustment of emissivity. The ability to adjust the device to the emissivity of different materials. The emissivity determines how much energy a given surface radiates at a certain temperature; it is expressed by numbers from 0 to 1 (coefficient 1 has an perfect “absolutely black body”). Without going into too much physical detail, we can say that if the instrument settings do not correspond to the actual emissivity of the surface being measured, the measurement results will also differ from the actual temperature. However, most of the surfaces that one has to deal with in fact — wood, brickwork, plastic, coated with paint and metal oxides — have an emissivity of 0.8 – 0.9; pyrometers are set to these indicators by default, and additional correction during measurements is generally not required. But the radiation index of polished metal and some other materials can be noticeably lower than these values, and the pyrometer must be adjusted separately for such surfaces. Well, anyway, if the maximum accuracy of measurements is critical for you, you should choose a device with adjustable emissivity and adjust it for each individual surface. There are special tables that allow you to determine this coefficient for different types of materials.

Backlight. The presence in the device of its own backlight. In this case, both conventional and ultraviolet illumination can be implied. The fir...st actually complements the pyrometer with a flashlight function and makes it easier to work in low light conditions. UV illumination, on the other hand, is primarily designed to detect refrigerant leaks in air conditioners and refrigeration units: many refrigerants contain an additive that glows in UV rays. The specific type of backlight for each model should be specified separately.

USB port. Standard USB connector for connecting the device to a computer, laptop, etc. Usually, to use the possibilities of such a connection, you need to install special software from the manufacturer's website. Connectivity may vary. So, the recording function is often encountered when the computer constantly monitors the readings of the device, building a chart or table of temperature fluctuations. Other devices may provide the ability to copy measurements from their own memory to a PC. The USB port can also be used to charge the battery (see "Power") and configure the pyrometer — for example, adjusting the emissivity (see above), calibrating, updating the firmware, etc. The specific set of capabilities in each case should be clarified separately.

RS-232. Also known as a COM port. Service connector for connecting the pyrometer to computers and some types of specialized equipment. Data can be transmitted via RS-232 in two directions: an external device can record pyrometer readings and, if necessary, control instrument settings from it.

Bluetooth. Bluetooth wireless technology is used for direct connection between different devices. Theoretically, the ways of using such a compound can be different; Specifically, in this case, Bluetooth is mainly used to connect the pyrometer to a smartphone, tablet or gadget and transfer measurement results to this gadget. To process the results, usually, you need to install a special application; it provides a variety of additional capabilities and is often more convenient than manual processing of results, especially when dealing with large amounts of data.
UNI-T UT300C often compared