Bosch UniversalTemp 0603683100
Bosch PTD 1 0603683020
Bosch UniversalTemp 0603683100Bosch PTD 1 0603683020
Compare prices 4
from £130.00 
Outdated Product
TOP sellers
Designgungun
Target designatorsingle pointcircular
Specs
Surface t measurements-30 – 500 °C-20 – 200 °C
Relative humidity measurement10 – 90 %
Ambient t measurement-10 – 40 °C
Distance to spot ratio1210
Response time500 ms
Measurement accuracy1.8 °C1 °C
Measurement accuracy1.8 %
Operating temperature-5 – 50 °C-10 – 40 °C
Functions
emissivity adjustment
emissivity adjustment
General
Power source2xAA2xAA
Case (bag)
Max. operating time9 h9 h
Dimensions171x101x54 mm180x124x53 mm
Weight220 g280 g
Added to E-Catalogdecember 2019march 2018

Target designator

The type of laser designator provided in the design of the pyrometer.

The laser pointer allows you to see exactly where the device is directed and the temperature of which particular area it measures. The options could be:

Single point. Target designator in the form of a single beam pointing to the centre of the measurement area. The simplest and cheapest option, however, not very accurate — in the sense that the user cannot accurately assess which area on the measured surface falls into the field of view of the pyrometer.

Two-point. Target designator in the form of two beams pointing to points along the edges of the measurement area. The location of the points can be horizontal (left and right) or vertical (top and bottom). Anyway, such a target designator already allows you to determine the size of the area that falls into the field of view of the device. However, it costs a little more than a single-point one, and therefore is less common.

Multi-point circular. Target designator in the form of several rays forming a circle of dots on the measured surface. This is the most complex and expensive, but also the most accurate option: the circle clearly shows the location and size of the measurement area.

Missing. The complete absence of any target designat...or in the design; it is necessary to direct such a device "by eye". This option is found exclusively in individual models of the most compact devices, which, in principle, are not designed for measurements at long distances.

Surface t measurements

The range of surface temperatures that the instrument can effectively measure.

In general, the meaning of this parameter is quite obvious. We only note that an extensive operating range is not always an advantage. First, it affects the cost of the device; secondly, when the range is extended, the measurement accuracy may deteriorate. So when choosing, you should not chase the maximum temperature range, but take into account real needs: for example, it hardly makes sense to choose a pyrometer with an upper limit of 500 °C for measuring the quality of thermal insulation and determining heat leaks in residential premises. It is conditionally possible to divide pyrometers into those that are for measuring low temperatures, and, accordingly, for high ones.

Relative humidity measurement

The range of relative humidity that the instrument can effectively measure. Humidity measurement is an additional function that allows you to more accurately assess the surrounding conditions, for example, the microclimate in a particular room.

Ambient t measurement

The range of ambient (ambient) temperatures that the instrument can effectively measure.

The ability to measure air temperature, provided in some models, allows the pyrometer to be used as a traditional indoor or outdoor thermometer. This function can be useful, in particular, when looking for problems with the thermal insulation of a room.

Distance to spot ratio

Instrument sighting index.

The sighting indicator is the ratio between the distance to the surface, the temperature of which is measured, and the diameter of the spot that enters the field of view of the device. For example, if at a distance of 2 m the device will cover a zone of 10 cm (0.1 m), then the sighting index will be 2 / 0.1 = 20.

When choosing for this parameter, it is worth considering the expected measurement conditions — the dimensions of the objects whose temperature is supposed to be measured, and the distances to them. At the same time, it is worth remembering that for accurate measurement, the measured surface must completely occupy the field of view of the pyrometer — otherwise the device will also “see” foreign objects, the radiation of which will distort the measurement results. Therefore, for long distances, models with high sighting rates are recommended — 40, 50, etc. If measurements are planned to be carried out at a distance of one or two metres, and the measured objects are quite large, you should pay attention to models with relatively small values of this parameter — 10 , 20 etc.

Response time

Approximate response time of the device, namely the time that elapses from pressing the measurement button until the results are shown on the display (or from a change in temperature to a change in the readings on the display, if we are talking about continuous measurement mode). In most cases, this parameter does not play a special role: even in the "slowest" devices, it does not exceed 1000 ms (1 s), which does not lead to any inconvenience. It is worth paying attention to the response time only if the device is planned to be used to measure the temperature of fast moving objects: the faster the reaction, the less time you have to keep the measured object in the field of view of the pyrometer, the lower the likelihood that this object can “jump out” from the field of view until the end of measurements.

Measurement accuracy

Temperature measurement accuracy provided by the pyrometer, in degrees. It is indicated by the maximum deviation in one direction or another, which the device can give out during operation. For example, if the specification says 1.5°C and the reading reads 80°C, the actual temperature could be between 78.5°C and 81.5°C. Thus, the smaller the number in this paragraph, the lower the error and the higher the accuracy of the device. At the same time, high accuracy has a corresponding effect on cost.

It should be noted that this designation often turns out to be very conditional, and the detailed characteristics may contain various clarifications regarding errors. So, the accuracy of measurements is often given simultaneously in degrees and in percentages with a wording like "± 2 °C or ± 2%, whichever value is greater." For details on percentage error, see Measurement Accuracy below. And this record means that the actual measurement error in degrees may turn out to be even higher than that directly stated in the characteristics — for example, 2% of 500 °C gives a deviation of ± 10 °C. In addition, there may be other refinements — for example, at sub-zero temperatures, the deviation can be ± 2 °C plus 0.05 °C for each degree below zero (that is, increase with decreasing temperature). So if high measurement accuracy is critical for you, you should carefully read the manufacturer's documentation.

Measurement accuracy

The accuracy of temperature measurements provided by the pyrometer, in percent. It is indicated by the maximum deviation in one direction or another, which the device can give out during operation. The percentage is taken from the actual temperature value; In fact, this means that the greater the deviation from zero, the higher the error can be. For example, at 100 °C an error of 2% gives a deviation of ±2 °C, and at 500 °C this value already reaches ±10 °C. However, this does not mean that when approaching zero, the error disappears — for this case, the measurement accuracy in degrees is given in parallel in the characteristics (see above). In this case, wordings like “± 2 °C or ± 2%, which of the values will be greater” are used; at low temperatures, when the percentage error will be unrealistically small (for example, for 20 °C, the same 2% will give only ± 0.4 °C), it is worth evaluating the accuracy of measurements by the error in degrees.

Operating temperature

The range of ambient air temperatures over which the instrument can perform its functions normally.

All modern pyrometers are guaranteed to work at room temperature. At the same time, they usually allow deviations from it within 15 – 20 °C — for example, in many models, the operating temperature range is claimed within 0 ... 40 °C. So you should pay attention to this indicator if the device is planned to be used at temperatures below zero, or vice versa, in hot conditions — not every model is able to work normally with one or another “extreme”.

Note that going beyond the range of permissible temperatures does not necessarily lead to a breakdown of the device. However, one should not deviate from these recommendations, at least in the light of the fact that under abnormal conditions the device begins to give too high an error, and there is no need to talk about any measurement accuracy.
Bosch UniversalTemp 0603683100 often compared
Bosch PTD 1 0603683020 often compared