Comparison Cooper&Hunter GWH07KF-K3DNA9D/I 21 m² vs Cooper&Hunter GWH07UA-K3DNA1A/I 21 m²

Add to comparison
Cooper&Hunter GWH07KF-K3DNA9D/I 21 m²
Cooper&Hunter GWH07UA-K3DNA1A/I 21 m²
Cooper&Hunter GWH07KF-K3DNA9D/I 21 m²Cooper&Hunter GWH07UA-K3DNA1A/I 21 m²
from $219.78 up to $235.60
Outdated Product
from $276.49 up to $296.40
Outdated Product
TOP sellers
Typemulti split systemmulti split system
Installationwallwall
Nominal capacity BTU70007000
Recommended room area21 m²21 m²
In box
indoor unit
indoor unit
Number of indoor units11
Features
Modes and programs
cooling, heating, dehumidification, ventilation
automode
night mode
cooling, heating, dehumidification, ventilation
automode
night mode
Functions
inverter compressor
timer
auto restart
inverter compressor
timer
auto restart
Performance
Cooling capacity2110 W2100 W
Heating capacity2610 W2200 W
Air flow550 m³/h450 m³/h
Noise level (max/min)40/24 dB37/25 dB
Refrigerant typeR410АR410А
Efficiency
Min. T for heating mode-15 °C-15 °C
General specs
Display+hidden
Indoor unit dimensions (WxHxD)
770x283x201 mm /weight — 8 kg/
860x299x153 mm /weight — 9.5 kg/
Color
Added to E-Catalogapril 2016april 2016

Cooling capacity

The heat output of the air conditioner when operating in cooling mode, in other words, the amount of heat energy that the unit can transfer from the room to the external environment when operating in this mode.

In general, cooling capacityup to 2 kW for modern air conditioners is considered very modest, 2–3 kW is low, 3–4 kW is medium, 4–6 kW is above average, and in the heaviest and most productive models this figure can be 6–8 kW and even more. Also, the conventional unit BTU can be used to denote capacity; in our catalogue, 1 BTU corresponds approximately to 0.293 W, however, for the convenience of choice, some deviations are allowed: for example, the 7000 BTU category includes units with power from 1.8 to 2.3 kW. Also on sale you can find air conditioners for 9000, 12000, 18000, 24000 BTU and more.

As for the choice for this indicator, the simplest formula is as follows: at least 100 W or 1/3 BTU of thermal power should fall on 1 m2 of the area of the room. Thus, to estimate the maximum area served, the power in watts should be divided by 100, and the power in...BTU should be multiplied by three. However, all these calculations are relevant only for standard residential/office premises with a ceiling height of about 2.5-3 m. For other conditions, you need to use a more complex formula, which is the sum of three parameters: 1) Q1 - the heat gain of the room itself, calculated by multiplying the area of the room by the height of the ceilings and the heat transfer coefficient (it ranges from 30 to 40 W, depending on the conditions); 2) Q2 - heat gain from operating equipment (on average, a third of the total power of all electrical appliances); 3) Q3 - heat gain from each person (from 100 W for sedentary work to 300 W for heavy physical exertion). More detailed recommendations regarding such calculations can be found in special sources.

A special case is represented by separately sold outdoor units of air conditioners (see "In box"). In this case, the capacity in cooling mode is the highest heating capacity of the indoor unit (in the same mode, of course) that can be connected to this outdoor unit. For multi split systems, respectively, the total indicator of all indoor units is taken into account.

Heating capacity

The power provided by the air conditioner in heating mode. It is indicated by the amount of thermal energy that the air conditioner can "pump" from the external environment into the room when operating in this mode. The most modest modern units have a heating capacity of 2 – 3 kW or even less, in the most performant it reaches 6 – 8 kW or more.

When evaluating this capacity, the same formulas are relevant that are used in calculating the power of traditional heating. So, for the full heating of an ordinary residential or office space (with ceilings of 2.5-3 m and normal thermal insulation), a thermal power of at least 100 W is required. There are more detailed calculation rules that allow you to calculate the necessary characteristics for other conditions. And if we are talking about a separately sold outdoor unit (see "In box"), then the meaning of this parameter is somewhat different. It indicates the maximum power of the indoor unit that can be connected to this outdoor unit to work in heating mode. For multi split systems, respectively, the total capacity of all indoor units is taken into account.

Recall that most air conditioners are not designed for use as full-fledged heating systems. However, such a unit can be a good addition to the main heating system. At the same time, air conditioners are less expensive than el...ectric heaters: the heater has an effective power equal to energy consumption, and the air conditioner consumes much less energy than it supplies to the heated room.

Also note that the unit BTU (more precisely, BTU/hour) can also be used to indicate the effective capacity (including in heating mode). 1 BTU (BTU/h) initially corresponds to 0.293 W, and the numbers in the characteristics of air conditioners correspond to thousands of BTU/h. For example, a 7 BTU air conditioner will produce an effective capacity of 7000 BTU/h, or about 2 kW. Such marking is convenient because BTU can easily determine the recommended area of a standard room (in m2): just multiply the figure indicated in the characteristics by 3. So, in our example, the power of 7 BTU will correspond to an area of 7*3=21 m2.

Air flow

The amount of air that an air conditioner can pass through itself in an hour.

This parameter depends on the power and the overall level of the device, but there is no strict dependence here: models with the same effective capacity may differ in air circulation speed. In such cases, it is worth proceeding from the fact that a higher speed contributes to uniform cooling/heating of the air and reduces the time required to create a given microclimate; on the other hand, higher-performing air conditioners use more energy, are larger and/or cost more.

Noise level (max/min)

The maximum and minimum level of noise produced by the air conditioner during operation; for split and multi split systems (see "Type"), by default, it is indicated for the indoor unit, and the data for the outdoor unit can be specified in the notes.

The noise level is indicated in decibels; this is a non-linear unit, so it is easiest to evaluate this parameter using comparative tables — they can be found in special sources. Here we note that, according to sanitary standards, the maximum level of constant noise for residential premises is 40 dB during the day and 30 dB at night; for offices, this figure is 50 dB, and in industrial premises higher volume levels may be allowed. So it is worth choosing an air conditioner according to this indicator, taking into account where and how it is planned to use it.

As for specific numbers, among the quietest modern air conditioners, there are models with a minimum performance of 23 – 24 dB, 22 – 21 dB, and sometimes even 20 dB or less. However, units at 31 – 31 dB and 33 – 34 dB are not uncommon; such loudness, usually, does not create discomfort in the daytime, but at night it is no longer desirable. However, in some cases, a louder air conditioner may be the best choice: noise reduction affects the cost, sometimes quite noticeably, and if the device...is not planned to be turned on at night, you can not overpay for additional noise reduction.

Display

A small screen installed on the indoor unit of the air conditioner. Such a display usually has basic functionality and displays a limited set of characters - numbers, some letters, sometimes also individual graphic icons. However, even such a screen can display quite a variety of information: set temperature, operating mode, timer settings, filter status, error codes, etc. Thanks to this, control is more convenient and visual.

Hidden display. When switched off, the hidden info display blends in with the surface design of the indoor unit of the air conditioner and remains invisible. In active mode, the characters on the screen are visible through a certain place in the texture and all the necessary information is displayed on the display. On most models, the screen can be turned off using the remote control, and this feature can often be set to automatically hide after a certain period of inactivity, which will be useful at night.

Indoor unit dimensions (WxHxD)

Dimensions of the indoor unit of the air conditioner in height, width and depth.

These dimensions allow you to estimate how much space you need to place the device. In this case, of particular importance — mainly for split and multi split systems with wall mounting is the width of the indoor unit. The fact is that in terms of the height and depth of the internal blocks, most of these systems differ slightly in general but the differences in width are much more noticeable. So, the narrowest models have a width of 76 – 80 cm or less, and the largest ones occupy 91 – 95 cm, and often more. At the same time, the more powerful the air conditioner, the wider it is, usually, but there is no rigid dependence here.