United Kingdom
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Solar Panels

Comparison EcoFlow 160W Portable Solar Panel 160 W vs EcoFlow 220W Bifacial Portable Solar Panel 220 W

Add to comparison
EcoFlow 160W Portable Solar Panel 160 W
EcoFlow 220W Bifacial Portable Solar Panel 220 W
EcoFlow 160W Portable Solar Panel 160 WEcoFlow 220W Bifacial Portable Solar Panel 220 W
Compare prices 6Compare prices 7
TOP sellers
Main
MC4 connector. The case can be used as a support stand. Moisture resistance class IP68. Operating temperature range -20° - 85°.
MC4 connector. Bifacial technology - the front side produces up to 220W, and the back up to 155W. The case can be used as a support stand. Moisture resistance class IP68. Includes carabiners for fastening.
Featuresportableportable
Typemonocrystallinemonocrystalline
Specs (STC)
Power (Pmax)160 W
220 W /facial; 155 W reverse/
Nominal voltage (Vmp)18.2 В18.4 В
Nominal power (Imp)8.8 А
12 А /facial; 8.4 A reverse/
Open-circuit voltage (Voc)21.4 В21.8 В
Short circuit current (Isc)9.6 А
13 А /facial; 8.8 A reverse/
Efficiency22 %23 %
Features
MC4 connector
Folding design
Support foot
Suspension system
WaterproofIP68IP68
Operating temperature-20 °C ~ +85 °C
General
Dimensions1570x680x24 mm1830x820x25 mm
Folded size680x420x24 mm
Weight5 kg9.5 kg
In boxcasecarabiners, case
Added to E-Catalognovember 2022november 2022

Specs (STC)

Standard Test Conditions (STC) are standard test conditions that reflect the operation of a solar panel under ideal conditions. As part of the tests, the weather of a clear sunny day with an air temperature of +25 °C, no wind, solar intensity of 1000 W/m² and an emission spectrum relative to air mass of 1.5 is simulated. The surface of the solar cell must be placed strictly perpendicular to the rays from the celestial body. Note that in real operation of the solar panel, such conditions are extremely rare. However, in general, the characteristics of the STC allow us to evaluate the "passport" parameters of the energy storage device.

Power (Pmax)

The amount of electricity in watts that a solar panel produces in one hour in tests using the STC method. The panel must provide the declared number of watts during normal operation.

Nominal voltage (Vmp)

The voltage reading on the voltmeter during a solar panel test at the nominal power level according to the STC method. This parameter, Vmp, stands for Voltage at Maximum Power and is measured in volts. It helps determine which type of batteries the panel is designed for — either 12 V or 24V.

Nominal power (Imp)

Ammeter reading during solar panel testing under STC conditions. The value of the rated current Imp (Current at Maximum Power) is measured in amperes.

Open-circuit voltage (Voc)

The voltage generated by the solar battery in idle mode, that is, without connecting the load. Behind the abbreviation Voc stands for Voltage Open Circuit.

Short circuit current (Isc)

The current value under the condition of zero voltage (Short Circuit Current).

Efficiency

Percentage of the maximum solar panel power to the incident radiation power produced. The efficiency parameter allows you to determine how efficiently the panel PV module converts solar energy into direct electric current.

Operating temperature

The temperature range in which the solar module functions normally. Exceeding the specified norms in any of the directions leads to a decrease in the productivity of energy generation, accelerated degradation of the panel, and the appearance of microcracks on its surface. For most solar panels, the operating temperature range is -40°C to +85°C.

Dimensions

Dimensions of the solar panel in unfolded form.
EcoFlow 160W Portable Solar Panel often compared