BASEUS CCNL050006 100 W
BLUETTI PV120 120 W
BASEUS CCNL050006 100 WBLUETTI PV120 120 W
Outdated Product
from £249.00 
Outdated Product
TOP sellers
Main
ETFE coating. Connector MC4. Moisture resistance class IP65. operating temperature range -10° - 65°. Cable length 3 m.
Featuresportableportable
Typemonocrystallinemonocrystalline
Specs (STC)
Power (Pmax)100 W120 W
Nominal voltage (Vmp)18 В19.6 В
Nominal power (Imp)5.5 А6.1 А
Open-circuit voltage (Voc)23.5 В24.4 В
Short circuit current (Isc)6.1 А6.43 А
Efficiency23.4 %
Features
MC4 connector
Folding design
Support foot
Suspension system
WaterproofIP66IP65
Operating temperature-10 °C ~ +65 °C-10 °C ~ +65 °C
General
Dimensions1588х396 mm1652x533 mm
Folded size533x470 mm
Weight3.6 kg5.7 kg
In boxcable1 panel
Added to E-Catalogjuly 2023november 2022

Specs (STC)

Standard Test Conditions (STC) are standard test conditions that reflect the operation of a solar panel under ideal conditions. As part of the tests, the weather of a clear sunny day with an air temperature of +25 °C, no wind, solar intensity of 1000 W/m² and an emission spectrum relative to air mass of 1.5 is simulated. The surface of the solar cell must be placed strictly perpendicular to the rays from the celestial body. Note that in real operation of the solar panel, such conditions are extremely rare. However, in general, the characteristics of the STC allow us to evaluate the "passport" parameters of the energy storage device.

Power (Pmax)

The amount of electricity in watts that a solar panel produces in one hour in tests using the STC method. The panel must provide the declared number of watts during normal operation.

Nominal voltage (Vmp)

The voltage reading on the voltmeter during a solar panel test at the nominal power level according to the STC method. This parameter, Vmp, stands for Voltage at Maximum Power and is measured in volts. It helps determine which type of batteries the panel is designed for — either 12 V or 24V.

Nominal power (Imp)

Ammeter reading during solar panel testing under STC conditions. The value of the rated current Imp (Current at Maximum Power) is measured in amperes.

Open-circuit voltage (Voc)

The voltage generated by the solar battery in idle mode, that is, without connecting the load. Behind the abbreviation Voc stands for Voltage Open Circuit.

Short circuit current (Isc)

The current value under the condition of zero voltage (Short Circuit Current).

Efficiency

Percentage of the maximum solar panel power to the incident radiation power produced. The efficiency parameter allows you to determine how efficiently the panel PV module converts solar energy into direct electric current.

Support foot

A device that allows you to install the solar panel at an angle to the horizontal, so that the sun's rays fall on it at an angle of about 90 °. In stationary solar panels, the support footboard is usually attached to the frame; in portable models, it is a separate cover. If the panel is sewn directly into the case, folding steps can be provided in such solar batteries.

Suspension system

Possibility of mounting a solar battery in a suspended state. As a rule, the suspension structure is implemented by means of holes in the panel for threading laces or installing carabiners.