UPS APC Smart-UPS SRT 10000VA SRT10KRMXLI 10000 VA
inverter UPS, rack, signal: sinusoid, power: 10000 VA, effective 10000 W, battery: 5.5 Ah, batteries 32, external battery connection, режим байпаса, sockets: C13/C14 with reserve, C19/C20 с резервом 4, terminal blocks, 112 kg

UPS APC Smart-UPS SRT 8000VA SRT8KRMXLI 8000 VA
inverter UPS, rack, signal: sinusoid, power: 8000 VA, effective 8000 W, battery: 5.5 Ah, batteries 32, external battery connection, режим байпаса, sockets: C13/C14 with reserve, C19/C20 с резервом 4, terminal blocks, 112 kg

UPS APC Smart-UPS SRT 10000VA SRT10KXLI 10000 VA
0
0
0
1
inverter UPS, rack, signal: sinusoid, power: 10000 VA, effective 10000 W, battery: 5 Ah, batteries 32, external battery connection, режим байпаса, sockets: C13/C14 with reserve, C19/C20 с резервом 4, terminal blocks, 112 kg

UPS APC Easy-UPS 3S 20 kVA E3SUPS20KHB 20000 VA
inverter UPS, signal: sinusoid, power: 20000 VA, effective 20000 W, battery: external battery connection, режим байпаса, sockets: terminal blocks, 122 kg

UPS APC Smart-UPS RT 15000VA SRTG20KXLI 20000 VA
inverter UPS, rack, signal: sinusoid, power: 20000 VA, effective 20000 W, battery: 9 Ah, batteries 16, external battery connection, режим байпаса, sockets: terminal blocks, 142.5 kg

UPS APC Smart-UPS RT 20kVA SURT20KRMXLI 20000 VA
inverter UPS, rack, signal: sinusoid, power: 20000 VA, effective 16000 W, battery: external battery connection, режим байпаса, sockets: C19/C20 с резервом 8, terminal blocks, 247.73 kg

UPS APC Smart-UPS RT 15kVA SURT15KRMXLI 15000 VA
inverter UPS, rack, signal: sinusoid, power: 15000 VA, effective 12000 W, battery: external battery connection, режим байпаса, sockets: C19/C20 с резервом 8, terminal blocks, 247.73 kg

UPS NGS FORTRESS 2000 V2 1200 VA 9 Ah
standby, signal: sinusoid, power: 1200 VA, effective 720 W, battery: 9 Ah, batteries 2, sockets: type F (Schuko), with reserve 4

UPS Eightt ES2000
standby, signal: sinusoid, battery: 7 Ah, batteries 2, sockets: type F (Schuko), with reserve 4

UPS PowerCool PCUPS1000VA 1000 VA
smart, signal: sinusoid, power: 1000 VA, effective 600 W, battery: 7 Ah, batteries 2, sockets: type G (UK), with reserve 3, C13/C14 with reserve

UPS PowerCool PCUPS650VA 650 VA
smart, signal: sinusoid, power: 650 VA, effective 390 W, battery: 7 Ah, batteries 1, sockets: type G (UK), with reserve 2

UPS Draper IN1000 1000 VA
smart, signal: similar to a sinusoid, power: 1000 VA, effective 1000 W, battery: external battery connection, sockets: type G (UK), with reserve 2, USB A

UPS NGS FORTRESS BUNKER 600 VA
standby, signal: sinusoid, power: 600 VA, effective 360 W, battery: 7 Ah, batteries 1, sockets: type F (Schuko), with reserve 3, without reserve 3

UPS NGS FORTRESS 1500 V2 1200 VA 7 Ah
standby, signal: sinusoid, power: 1200 VA, effective 720 W, battery: 7 Ah, batteries 2, sockets: type F (Schuko), with reserve 4

UPS Eightt ES650 650 VA
standby, signal: sinusoid, power: 650 VA, battery: 7 Ah, batteries 1

UPS PowerCool PCUPS1200VA 1200 VA
smart, signal: sinusoid, power: 1200 VA, effective 720 W, battery: 7 Ah, batteries 2, sockets: type G (UK), with reserve 3, C13/C14 with reserve

UPS PowerCool PCUPS850VA 850 VA
smart, signal: sinusoid, power: 850 VA, effective 510 W, battery: 7 Ah, batteries 1, sockets: type G (UK), with reserve 2

Apc Metered Rack Power Distribution Units (Pdus) Provide Active Metering To Enable Energy Optimization And Circuit Protection. User-Defined Alarm Thresholds Mitigate Risk With Real-Time Local And Remo more→te Alerts To Warn Of Potential Circuit Overloads. Metered Rack Pdus Provide Power Utilization Data To Allow Data Center Managers To Make Informed Decisions On Load Balancing And Right Sizing It Environments To Lower Total Cost Of Ownership. Metered Rack Pdus Include Real Power Monitoring A Temperature/Humidity Sensor Port Locking Iec Receptacles And Ultra Low Profile Circuit Breakers. Users Can Access And Configure Metered Rack Pdus Through Secure Web Snmp Or Telnet Interfaces Which Are Complimented …
31,768.00Buy!
£
Amazon.co.uk
Delivery: to United Kingdom
Report
UPS topology: double conversion (online) Battery technology: Sealed Lead Acid (VRLA) Weight: 2.5 kg Display: LCD AC outlet(s) quantity: 11 AC outlet(s)
1,603.82Buy!
£
Smartteck.co.uk
Delivery: to United Kingdom
Report
Origin Storage Uniti Power Symphony Online Double Conversion 230V 2U 3kVA / 2.7kW 8 x IEC C13 + 1 x IEC C19
95.99Buy!
£
Tradeinn.com
Delivery: in United Kingdom
Report
EU PLUG.Woxter UPS 1200 VA.UPS topology:Line-Interactive, Output power capacity:1.2 kVA, Output power:720 W.AC outlet types:Type F, AC outlets quantity:3 AC outlet(s).Battery capacity:7 Ah, Battery vo more→ltage:12 V, Battery recharge time:8 h.Form factor:Mini Tower, Product colour:Black, Housing material:Metal.Width:120 mm, Depth:355 mm, Height:195 mm.
PowerWalker PWB12 battery series is designed to work with UPS solutions. It is a high quality valve-regulated lead acid battery with high corrosion resistance and special exhaust structure. The sealin more→g technology with high discharge capacity offers long life, reliability and safety. Batteries are flexible for installation and maintenance and easy to handle. FEATURES: Rechargeable Battery:- Number of Batteries: 1 Type:- Type: UPS Battery General:- Width (mm): 65- Height (mm): 99- Depth (mm): 151- Weight (kg): 2,18
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are more→(8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
667.90Buy!
£
Smartteck.co.uk
Delivery: to United Kingdom
Report
Origin Storage Uniti Power Symphony Online Double Conversion 230V 2U 1.5kVA / 1.5kW 4 x IEC C13
24 more item(s)
Filters
Price
from£ up to£ 
Brands
Type
Max. output power
Effective output power
Output waveform
Battery capacity
Backup sockets
Socket type
C13/C14 backup sockets
Other connectors
Features
Control interfaces
Full load operating time
Switching to battery
Battery charging current
Protection
Form factor
more
Input voltage
Battery type
Number of batteries
Depth
Width
Height
Noise level