reverse polarity protection short circuit protection overload protection
General
Display
monochrome
Cooling
passive
Noise level
25 dB
Casing protection class
IP65
Operating temperature
-30 °C ~ +60 °C
Dimensions
511x415x175 mm
Weight
20.5 kg
Added to E-Catalog
march 2024
The information in the model description is for reference purposes. Always clarify the specifications and configuration of the product with the online store manager before purchasing. Catalog General Electric 2025 - new arrivals, bestsellers, and the most relevant models General Electric.
on-grid, three-phase, 8000 W, connection: RS485, LAN (RJ45), Wi-Fi, MPPT controller, monitoring, work at -t °C, defence from: overload, short circuit, reverse polarity, IP65, 511x415x175 mm
hybrid inverter, single-phase, 12000 W, monitoring, parallel operation, function UPS, work at -t °C, defence from: overload, overheating, short circuit, 572x488x344 mm
hybrid inverter, single-phase, three-phase, 6000 W, connection: RS485, LAN (RJ45), Wi-Fi, MPPT controller, monitoring, function UPS, work at -t °C, defence from: overload, overheating, short circuit, reverse polarity, IP66, 595x529x180 mm
hybrid inverter, single-phase, 4000 W, connection: LAN (RJ45), monitoring, parallel operation, work at -t °C, defence from: overload, overheating, short circuit, IP22, 565x320x149 mm
hybrid inverter, single-phase, 4200 W, connection: RS232, LAN (RJ45), function UPS, work at -t °C, defence from: overload, short circuit, 444x300x100 mm
hybrid inverter, single-phase, 430 W, connection: LAN (RJ45), monitoring, parallel operation, work at -t °C, defence from: overload, overheating, short circuit, IP21, 311x182x100 mm
hybrid inverter, single-phase, 700 W, connection: LAN (RJ45), monitoring, parallel operation, work at -t °C, defence from: overload, overheating, short circuit, IP21, 360x240x100 mm
hybrid inverter, single-phase, 1300 W, connection: LAN (RJ45), monitoring, parallel operation, work at -t °C, defence from: overload, overheating, short circuit, IP21, 470x265x120 mm
on-grid, single-phase, three-phase, 12500 W, connection: RS485, USB, LAN (RJ45), Wi-Fi, MPPT controller, monitoring, parallel operation, work at -t °C, defence from: overload, short circuit, reverse polarity, IP66, 725x510x225 mm
hybrid inverter, three-phase, 8000 W, connection: RS485, Wi-Fi, MPPT controller, monitoring, work at -t °C, defence from: overload, short circuit, reverse polarity, IP66, 516x415x180 mm
hybrid inverter, three-phase, 8000 W, connection: RS485, USB, LAN (RJ45), Wi-Fi, MPPT controller, monitoring, work at -t °C, defence from: overload, overheating, short circuit, reverse polarity, IP65, 519x449x198 mm