Dark mode
United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heaters   /   Fan Heaters

Comparison Electrolux EFH/C-5125 vs Electrolux EFH/C-5120

Add to comparison
Electrolux EFH/C-5125
Electrolux EFH/C-5120
Electrolux EFH/C-5125Electrolux EFH/C-5120
Outdated Product
from $30.00
Outdated Product
TOP sellers
Main
Compact dimensions. Proprietary Storage O2 heating element technology. Soft coated rotary switches.
Typefan heaterfan heater
Heating elementceramicceramic
Controlsrotary knobrotary knob
Power supplymainsmains
Max. power1500 W2000 W
Heating area15 m²25 m²
Features
Features
thermostat
fan mode
thermostat
fan mode
Safety system
overheat protection
overheat protection
More specs
Installation
floor
floor
Dimensions (HxWxD)24.5x18.5x10.5 cm24.5x19.6x18.1 cm
Weight0.9 kg1.4 kg
Color
Added to E-Catalogdecember 2016october 2013

Max. power

The maximum power of the heater. The meaning of this parameter depends on the device type and power supply (see above). So, for most types of heaters, we are talking about the highest power output. However, for fan heaters, this parameter also includes the power of the fan motor, and the heating capabilities are somewhat more modest than the claimed maximum power (although not by much). For electric models, the maximum power also corresponds to the maximum power consumption, which determines the connection requirements: for example, for devices of 3.5 kW and more, ordinary sockets are no longer suitable, and some require not 230 V but 400 V.

However, the key point determined by the power of the heater, is the intensity of heating and the ability to effectively heat a particular room. To select the appropriate model, there are special formulas. So, if we are talking about a city apartment or a small office space with a ceiling height of about 2.5 m, then we can assume that a heating power of at least 100 W is required per 1 m² of area. For other situations, more complex methods are used, taking into account the volume of the room, the degree of thermal insulation, climate and solar heating, etc.; they can be found in special sources. Also note that for IR heaters (see "Type"), their own calculation methods are used — this is due to the specific format of work.

Heating area

A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout and equipment, actual values may vary significantly. However, this item represents the maximum recommended area of the room that the device can effectively heat. This parameter directly depends on the maximum power (see above). It is worth noting that the actual efficiency of the heater in most cases depends not on the area, but on the volume of the room. In light of this, the heating area can only be specified for a certain ceiling height. In most cases, manufacturers mean 2.5 m - this is the standard ceiling height in city apartments. If the ceilings are much higher, the heating area must be recalculated using special formulas. In general, it is worth considering that 1 kW is comfortable for 10 m², however, manufacturers may slightly overestimate the heating area data.
Electrolux EFH/C-5125 often compared
Electrolux EFH/C-5120 often compared