United Kingdom

Other Sound & Hi-Fi

 prices on 7472 models  
Show
Apc Metered Rack Power Distribution Units (Pdus) Provide Active Metering To Enable Energy Optimization And Circuit Protection. User-Defined Alarm Thresholds Mitigate Risk With Real-Time Local And Remo more→te Alerts To Warn Of Potential Circuit Overloads. Metered Rack Pdus Provide Power Utilization Data To Allow Data Center Managers To Make Informed Decisions On Load Balancing And Right Sizing It Environments To Lower Total Cost Of Ownership. Metered Rack Pdus Include Real Power Monitoring A Temperature/Humidity Sensor Port Locking Iec Receptacles And Ultra Low Profile Circuit Breakers. Users Can Access And Configure Metered Rack Pdus Through Secure Web Snmp Or Telnet Interfaces Which Are Complimented …
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remo more→te alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring a temperature/humidity sensor port locking IEC receptacles and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web SNMP or Telnet Interfaces which are complimented …
NetShelter Switched Rack PDUs Features & BenefitsN/AManageabilityN/A1% Metering AccuracyN/AProviding the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1 1% meteri more→ng accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.N/AGigabit Ethernet ConnectivityN/A9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.N/ANetwork Port SharingN/AConnect and manage …
APC Basic Rack PDU Input: 230V Input Connections: IEC-320 C20 Cord Length: 10 feet ( 3.05 meters ) Output: 230V Output Connections: IEC 320 C13IEC 320 C19.

Includes: Installation more→guide Rack Mounting brackets Toolless Mounting Kit.
APC Basic Rack PDU Input: 230V Input Connections: IEC 309 16A 2P+E Cord Length: 3 feet ( 0.91 meters ) Output: 230V Output Connections: IEC 320 C13 IEC 320 C19.

Includes: Installation more→guide Toolless Mounting Kit.
Easy Switched Rack Power Distribution Units (Rack PDU) provide on/off outlet switching, advanced power management, load monitoring and much more features than the average power strip. Includes: Cable, more→Horizontal mounting brackets, Installation guide- Remote Individual Outlet Control: Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).- Remote Management Capabilities: Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote …
Features:Output Connections:- (4) IEC 60320 C19- (20) IEC 60320 C13- Nominal Output Voltage: 230V- Nominal Input Voltage: 200V, 208V, 230V- Input Connections: IEC 60309 32 A 2P + E- Cord Length: 3mete more→rs- Easy PDU, Metered, Zero U, 32A, 230V, (20)C13 & (4)C19;IEC309- Easy Metered Rack Power Distribution Units (Rack PDU) provide real-time remote monitoring, power management of connected loads, and much more features than the average power strip.- Includes: Installation guide, Toolless mounting kit, User manual, Vertical mounting bracketsRemote Management Capabilities:- Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. A…
Surgearrest Essential Surge Protector 6x BS1363 Outlets 760 Joules 6.5ft/2.0m Extension Cord BS1363 Plug
Description:

APC Basic Rack PDU Input : 120 208 230V Input Connection Type : IEC-320 C20 Cord Length : 8.2 feet ( 2.5 meters ) Output : 120 208 230V Output Connections : (10)IEC 32 more→0 C13 (2)IEC 320 C19

Features: 19 inch Rack-Mountable Low Cost Power Distribution Vertical Mounting Capabilities

Includes: Cord Retention Clips Rack Mounting Brackets User Manual

Output Voltage(s) (main only) - 120 208 230 V

Maximum Total Current Draw per Phase - 16 A

Output Connections - (10)IEC 320 C13; (2)IEC 320 C19

Always on Outlets - 12
Overload Protection

Input:

Nominal input voltage - 120 208 230

Input frequency (Hz) - 50/60 Hz

Input Connection
Description - APC Basic Rack PDU Input : 208 230V Input Connection Type : IEC-320 C14 Cord Length : 6.5 feet ( 1.98 meters ) Output : 208 230V Output Connections : (15)IEC 320 C13

 more→Features - Low Cost Power Distribution Toolless Mounting Capabilities Vertical Mounting Capabilities

Includes - Installation Guide Rack Mounting Brackets Toolless Mounting Kit

Output:

Output Voltage(s) (main only) - 208 230 V

Maximum Total Current Draw per Phase - 10 A

Output Connections - (15)IEC 320 C13

Input:

Nominal input voltage - 208 230

Input frequency (Hz) - 50/60 Hz

Input Connection Type - IEC-320 C14

Cord Length - 6.5 feet ( 1.98 meters )

Acceptable
Features:
Single input power source
Toolless Mounting Capabilities
Vertical Mounting Capabilities
-Toolless mounting capability.
-Vertical mounting capability.
-Rack-Mountable: Includes horizontal vertical and toolless-mount varieties. Puts power where it is needed most - in the rack more→s near the equipment.
-Single input power source: Supply power from one branch whip to multiple pieces of equipment conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
-Wide range of input and output connections: Product family includes a variety of input and output connections to distribute 120V 208V or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements.
Provides protection of connected equipment from power surges on the data lines.

Reduces line noise that can cause data loss and keyboard errors.

APC surge protectors unde more→rgo stringent testing by IEEE and are awarded "let-through ratings" which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance. The APC Essential SurgeArrest series offers optimal performance with a let-through rating of less than 330V for North American products and a rating of less than 15% for products sold worldwide. All APC products comply with …
Protection of data lines (Ethernet Coaxial and Phone lines) ensures complete protection of your equipment from surges. It is very important to protect your equipment from back door electric surges tra more→veling through data lines as they can be as damaging to your equipment as surges traveling over power lines.

Reduces line noise that can cause data loss and keyboard errors.

APC surge protectors undergo stringent testing by IEEE and are awarded "let-through ratings" which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance.
24.66Buy!
£
Quzo.net
Delivery: to United Kingdom
Report
SurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage excess more→power cannot reach your equipment. Unlike the APC SurgeArrest products most surge suppressors continue to let power through even after circuits have been damaged leaving your equipment exposed to other damaging surges.

APC surge protectors undergo stringent testing by IEEE and are awarded "let-through ratings" which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings …
APC surge protectors undergo stringent testing by IEEE and are awarded "let-through ratings" which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage sp more→ike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance. The APC Essential SurgeArrest series offers optimal performance with a let-through rating of less than 330V for North American products and a rating of less than 15% for products sold worldwide. All APC products comply with local agency safety requirements including UL in North America and CE/Kema/Gost/C-tick/A-Tick/Telepermit in their respective regions.

SurgeArrest …
24 more item(s)
Filters
Price
from£ up to£ 
Brands
All brandsMain brands