Dark mode
United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Thermostats

Comparison Auraton 3021 vs Auraton 2025

Add to comparison
Auraton 3021
Auraton 2025
Auraton 3021Auraton 2025
Outdated ProductOutdated Product
TOP sellers
Suitable for
gas boiler
electric boiler
heater / underfloor heating
gas boiler
electric boiler
 
Specs
Typeelectronicelectronic
Connectionwiredwired
Mountingon wallon wall
Temp adjustment range0 – 35 °C4 – 35 °C
Hysteresis0.2 – 0.4 °C0.2 – 0.4 °C
Timer typeweeklyweekly
Programmable cycles per day624
Minimum increment60 min60 min
More features
Features
display
 
frost protection
 
temp sensor calibration
display
holiday mode
frost protection
operating hours counter
 
Power sourcebatterybattery
Added to E-Catalognovember 2017november 2017

Suitable for

The type of equipment for which the regulator is suitable.

Modern thermostats and automation systems can be used for:

- For different types of boilers — gas, electric, solid fuel.
- For heaters and underfloor heating - for both at the same time: the control features in both cases are very similar, which makes it easy to combine them in one device.
- For pumps — namely for circulation pumps of heating systems.
— For heat pumps. A heat pump provides heat transfer from the environment to the room, providing heating. (Air conditioners work on a similar principle, but their main task is cooling).
— For fancoils. A fancoil is a device that cools or heats air by passing it through a system of pipes with a coolant circulating through them. And for the necessary heating or cooling of the coolant, another component of the system is responsible - a chiller, usually installed outdoors. A feature of such climate systems is that most of them can be used not only for heating in the cold season but also for cooling in the hot season.
— For outdoor system. Regulators for various climatic equipment installed outdoors. These can be, for example, anti-icing systems, devices f...or heating pipelines, chillers for chiller-fan coil systems, etc.

In many models, several options are combined at once; for example, most devices for electric boilers are quite compatible with gas boilers.

In any case, it is the first criterion that one should pay attention to when choosing.

Temp adjustment range

It is the range in which the air temperature can be set on the regulator. The choice for this indicator depends on the expected conditions in the room. So, in a residential building, the lower temperature limit at the level of 5–10 °C is quite sufficient; the upper limit is within 30–40 °C (regardless of whether we are talking about air or floor temperature). But in control devices designed for industrial use, this range will be much wider — from sub-zero temperatures to the upper limit of 100 – 125 °C.

Programmable cycles per day

The largest number of individual cycles that the thermostat timer can set in one day.

The cycle is the period during which the thermostat operates on one set of settings. For example, if there are 2 cycles, you can provide turning off the heating while you are at work and turn it on shortly before returning home. However, most thermostats provide a noticeably larger number of cycles — up to 24.

Note that in weekly timers (see "Timer type") this parameter may differ depending on the day of the week. For example, weekdays usually have more extensive settings than weekends.

Features

Display. The presence of its own screen in the design of the regulator. Such a screen is usually a simple LCD matrix with segment digits. However, even on such a screen, very diverse data can be displayed (including temperature with an accuracy of fractions of a degree), and this function significantly expands the capabilities of the thermostat and makes it more convenient. Note that it makes sense to install the display primarily in electronic models (see "Device type"), for such thermostats it is almost mandatory (but in mechanical ones, on the contrary, it is almost never used).

Protection of the pump from "souring". During non-working hours — for example, between heating seasons — deposits can form on the parts of the circulation pump of the heating system, which can make it difficult to rotate the impeller, reduce the efficiency of the pump, or even disable it altogether. This phenomenon is called "souring". To avoid it, automatic regulators may provide protection against acidification: periodically (once every few weeks) the pump is turned on for a short time, which prevents the formation of deposits (and removes those that have already formed).

Holiday function. A special regime provided for in case of a long absence of people in the house (for example, during a vacation — hence the name). In holiday mode, you can set a certain temperature to...be maintained for several days (for example, a week; the maximum duration depends on the thermostat model). At the same time, in some models, this function is combined with frost protection (see below) and allows you to set only the minimum temperature (usually 5 °C); in others, the holiday temperature can be programmed.

— Random mode. A mode that provides for the inclusion of various heating functions in a random order (but without causing critical loads on the heating system). The most popular use of this feature is to simulate that someone is at home; this can stop intruders planning a theft in the absence of the owners.

— Management via the Internet. Ability to control the controller via the Internet. The device itself is usually connected to the network via Wi-Fi, and the control features may be different. For example, in some models you need to use a proprietary application installed on a smartphone or tablet, in others it is enough to open a special page in any browser. However, anyway, this function allows you to control the heating system remotely, from anywhere in the world. This can be extremely convenient in unforeseen situations — for example, if during the absence of the owner on the street it gets warmer. In addition, additional features such as advanced timer programming may be available with Internet control.

— Frost protection. A function that prevents freezing of the coolant in heating systems. Freezing water expands, which can lead to mechanical damage and depressurization of the system. To avoid this, regulators with this function are able to "monitor" that the temperature of the coolant does not fall below 5 °C, and, if necessary, turn on the heating to maintain the temperature. This function is relevant primarily for cases when the disconnected heating system must be left unattended for a long time during the cold season.

— Protection from children (blocking). The ability to lock the control panel of the regulator so that a curious little child cannot knock down its settings. The lock, usually, is turned on and off in such a way that an adult, but not a child, can easily do it — for example, by simultaneously pressing certain keys.

— Heater operating hours counter. Built-in counter that tracks the total heating time. This feature makes it much easier to keep track of the operating mode and heat costs, eliminating the need for the user to keep records manually and allowing you to track working hours even when there is no one nearby.

— Sensor calibration t. Possibility to calibrate the temperature sensor of the thermostat. In fact, situations may arise when the readings of the temperature sensor for one reason or another differ from the actual temperature in the room — for example, the controller is installed near an electrical appliance that generates heat and knocks down the setting, and neither device can be moved. For such cases, calibration is provided — an amendment to the readings of the temperature sensor. For example, if the thermometer in the middle of the room reads 20°C and the regulator's sensor reads 22°C, you can correct the thermostat to -2°C and the temperature displayed on the regulator will correspond to the true temperature. Of course, the correction can also be taken "in the mind" without reconfiguring the device; however, most often it is easier to set the necessary parameters in advance and not get confused in the calculations.
Auraton 3021 often compared