Add to comparison
Luxeon EDC-1000 1 kVA / 700 W
Powercom TCA-2000 2 kVA / 1000 W
Luxeon EDC-1000 1 kVA / 700 WPowercom TCA-2000 2 kVA / 1000 W
Outdated Product
from $27.88 up to $34.24
Outdated Product
TOP sellers
Main
Protection against high frequency interference.
AVR typetRIACrelay
Input voltage230V (1 phase)230V (1 phase)
Power700 W1000 W
Power1 kVA2 kVA
Specs
Input voltage range90 – 270 V176-264 V
Output voltage accuracy (±)4 %5 %
Efficiency95 %
Voltmeterdigitalis absent
Sockets
Grounded sockets11
Protection levels
Protection
overheating
high frequency interference
short circuit
overload
over / under voltage
 
high frequency interference
short circuit
overload
over / under voltage
General
Installation
floor
floor
Coolingpassivepassive
Dimensions225x110x190 mm115x93x136 mm
Weight4.21 kg2 kg
Added to E-Catalogmay 2022march 2014

AVR type

Relay. Such devices have a transformer with a set of contacts, each of which is responsible for a certain voltage value. Thus, the adjustment is carried out stepwise. And for switching between groups of contacts, a specialized relay is responsible, in full accordance with the name. Being simple and fairly inexpensive devices, relay regulators have high speed (see “Response speed”) and a wide input voltage range (see below). At the same time, the relay gives a rather large error (see "Output voltage accuracy") and is poorly adapted to work with high currents and sudden voltage surges (for example, when using a welding machine) — the contact group is highly likely to burn out. Therefore, models of this type are mostly designed for simple conditions where neither high accuracy nor power is required — for example, they are well suited for connecting individual household appliances. In addition, we note that the operation of the relay is often associated with a significant level of noise (primarily due to the characteristic "click"); this can cause serious inconvenience in residential use.

Thyristor. The device of thyristor stabilizers is in many ways similar to the relay stabilizers described above: in particular, there is the same transformer with a set of separate outputs for step adjustment. However, switching between the windings is carried out not with the help of a relay, but with the help of...semiconductor devices — thyristors. The principle of their operation is also similar to a relay: a thyristor is able to close and open a circuit with powerful currents, receiving control commands using weak signals. The main design difference of thyristor stabilizers, which gives them an advantage over relay ones, is the absence of a contact group. This allows you to connect a fairly powerful load to such devices, the accuracy of their work is very high, and the noise during switching, unlike relay circuits, is practically absent. On the other hand, thyristors are sensitive to overheating and require the installation of active cooling systems (see below), which accordingly affects the price and dimensions of the device.

— Triac. Stabilizers built on triacs (symmetrical thyristors). In fact, they are a variety of the thyristor devices described above, and from the practical point of view, they do not noticeably differ from them in any way — neither in advantages nor in disadvantages.

Electromechanical. The operation of such stabilizers is based on the operation of an electric motor (sometimes called a servomotor), which moves a special carbon contact directly along the transformer windings. Depending on the position of the contact, the number of turns of the winding included in the work changes; This is how the voltage is adjusted. Such models are considered one of the best in terms of price / quality ratio, they combine low cost with excellent accuracy and smoothness of adjustment. At the same time, the response speed in them directly depends on the degree of change in the input voltage: the stronger the jump, the greater the distance the brush must travel along the windings. Accordingly, electromechanical stabilizers are poorly suited to work with sharp drops in the network, and therefore, in order to avoid unpleasant consequences, the input voltage range (see below) is usually rather narrow. In addition, the brush is erased with constant movement, which requires periodic cleaning of the transformer and replacement of the brush itself; however, such a need does not arise often and usually does not cause difficulties. The operation of the servomotor creates some noise, but in general models of this type are quieter than relay ones (although noticeably louder than solid-state ones).

ferroresonant. One of the first types of stabilizers mass-produced. The design of such a device is based on a pair of coils, reminiscent of a classic transformer. The characteristics of the coils are selected in such a way that when the input voltage is exceeded, the “extra” part of the magnetic flux from the input coil is diverted into the so-called magnetic shunt, and the magnetic flux through the output coil (and, accordingly, the voltage at its outputs) remained constant. Due to this, ferroresonance models have high speed and smooth operation, good accuracy, as well as a simple and inexpensive design. On the other hand, such stabilizers are not capable of delivering a smooth sinusoidal current, they are highly dependent on the frequency of the input current, they create noise on the line (which requires the use of filters when connecting sensitive electronics), they have a small range of input voltages and load powers (they are unable to operate idle or with overload). In addition, devices of this type are heavy and bulky. As a result, they are considered obsolete and are used relatively rarely.

Combined. A kind of stabilizers that combines elements of relay and electromechanical models in the design. Usually, for small voltage surges, they use tuning with an electric motor; the relay, in turn, plays the role of insurance and is activated in case of significant deviations that the electromechanical part cannot cope with “alone”. Thanks to this, in one device it was possible to combine the advantages of both options — high tuning accuracy and a wide range of input voltages. However this type of stabilizer also inherited some disadvantages — in particular, the need to clean the brush and noise when the relay is triggered (although the latter happens less often than in purely relay models). In addition, the cost of such units is usually quite high.

Double conversion. The principle of operation of this type of stabilizer is to convert AC to DC (using a rectifier) and then back to AC (using an inverter). The inverter is set up to provide a near reference voltage and a sine wave over the entire operating range of the input voltage. Thus, the main advantage of double conversion stabilizers is the high accuracy of the output signal, such devices are suitable even for delicate components such as TVs or speakers. In addition, the input voltage range turns out to be quite wide, the reaction to power surges is almost instantaneous, and due to the absence of moving parts, the stabilizer operates quietly and “lives” for a long time. The main disadvantages of such devices are high cost and relatively low efficiency (about 90%).

Power

The maximum active load power allowed for this model.

Active power is the power that in AC appliances is spent on useful work or on heat generation. In addition to it, such devices also consume reactive power — it goes to the operation of specific components, primarily capacitors and inductors. Apparent power, denoted in volt-amperes (kilovolt-amperes), is the sum of active and reactive, see below about it. Here we note that in simple everyday situations, there is enough data on active power indicated in watts for calculations. In particular, it is this parameter that is considered the key when choosing stabilizers for washing machines and dishwashers : in the first case, power from 2 to 5 kW is considered optimal, in the second — from 1.8 to 2.5 kW.

Anyway, the total active power of the connected load should not exceed the figures indicated in the characteristics of the stabilizer. For a full guarantee, it's ok to take a certain margin, but this margin should not be too large — an increase in the allowable power significantly affects the dimensions, weight and price of the device. Also note that there are formulas that allow you to convert the active power consumption into total power, taking into account the type of connected electrical appliance; these formulas can be found in special sources.

Power

Maximum apparent load power allowed for this model

In electrical engineering, full power is called, which takes into account both active and reactive power; the first type of power is discussed above, and the second can be described as the effect of windings, inductors and capacitors on the operation of AC networks. Apparent power is the main parameter for calculating loads on equipment in professional electrical engineering; it is usually denoted in volt-amperes (VA), in the case of stabilizers — in kilovolt-amperes (kVA). Note that for convenience, different types of power in electrical engineering are denoted by units with different names. That is why the power in W indicated in the characteristics of the stabilizer is usually not equal to its power in VA.

When choosing a stabilizer for some household appliances, it is quite enough to have active power data, but if possible it is better to use the full one. In particular, it is this parameter that is key when looking for a stabilizer for a refrigerator or a stabilizer for a boiler : in the first case, 0.4 – 1 kVA is considered the optimal value, in the second — from 0.1 to 0.7 kVA. However, anyway, it is necessary to choose a specific model in such a way that its total power is not lower than the total power of the entire connected load — and it is better to have a reserve (in case of unforeseen circumstances or connecting additional eq...uipment). At the same time, note that powerful models are distinguished by large dimensions and weight, and most importantly, high cost; therefore, it does not always make sense to chase the maximum numbers.

Also note that there are formulas that allow you to derive the optimal total power of the stabilizer based on data on active power and type of load; they can be found in special sources.

Input voltage range

The voltage range at the input of the stabilizer, at which it is able to operate in normal mode and supply a constant voltage of 230 or 400 V to the load (depending on the number of phases, see above). The wider this range — the more versatile the device, the more serious power surges it can extinguish without going beyond the standard operating parameters. However, note that this parameter is not the only, and not even far from the main indicator of the quality of work: a lot also depends on the accuracy of the output voltage and the response speed (see both points below).

Also note that some models may have several modes of operation (for example, with 230 V, 230 V or 240 V output). In this case, the characteristics indicate the "general" input voltage range, from the smallest minimum to the largest maximum; the actual ranges for each particular mode will vary.

In addition, there are stabilizers that can operate outside the nominal input voltage range: with a slight deviation beyond its limits, the device provides relatively safe output indicators (also with some deviations from the nominal 230 or 400 V), but if the drop or rise becomes critical, it works appropriate protection (see below).

Output voltage accuracy (±)

The largest deviation from the nominal output voltage (230 V or 400 V, depending on the number of phases), which the regulator allows when operating in the normal input voltage range (see above). The smaller this deviation, the more efficiently the device works, the more accurately it adapts to “changes in the situation” and the less voltage fluctuations the connected load is exposed to.

When choosing for this parameter, it is worth considering first of all how demanding the connected devices are for voltage stability. On the one hand, high stability is good for any device, on the other hand, it usually means a high price. Accordingly, it usually does not make sense to buy an advanced stabilizer for an unpretentious load like light bulbs and heaters, but for sensitive devices like audio systems or computers, it can be very useful.

Efficiency

The efficiency of the stabilizer is the ratio, expressed as a percentage, between the amount of electricity at the output of the device to the amount of energy at the input. In other words, efficiency describes how much of the energy received from the network the device transfers to the connected load without loss. And losses during operation will be inevitable — firstly, not a single transformer is perfect, and secondly, the control circuits of the stabilizer also require a certain amount of energy to work. At the same time, all these costs are quite small, and even in relatively simple modern models, the efficiency can reach 97-98%.

Voltmeter

The type of voltmeter provided in the stabilizer design, or rather the type of scale used by this device. This voltmeter itself allows you to monitor the voltage - usually both at the input and at the output - which makes it easier to control the stabilizer's operation. For this purpose, two separate scales are most often provided, but there are also "single" voltmeters, with a switch to select between input and output voltage. And by scale type, there are the following options:

— Analog. Analog voltmeters are equipped with a traditional scale — with divisions and an arrow applied to it. They are simpler and cheaper than digital ones, but less accurate — even in the thinnest devices, the error in indications can be 5-10 V only due to the peculiarities of reading information from such a scale. And in some inexpensive models, analog voltmeters play the role of general indicators rather than precision devices. At the same time, for most everyday tasks, such accuracy is quite sufficient.

— Digital. In such voltmeters, the role of the scale is played by a digital indicator, on which voltage values can be displayed with an accuracy of up to a volt — this is the main advantage of this option over the analog one. Among the disadvantages, it is worth noting the complexity and rather high cost of digital indicators. In addition, such high accuracy can be critical in the professional sphere, but in everyday life it is not always...required. Accordingly, in inexpensive low-power stabilizers, a digital voltmeter is often more of a marketing ploy than a real necessity.

Protection

- From overheating. Protection that prevents the critical temperature rise of individual components of the stabilizer - for example, in case of overload, short circuit or failure in the cooling system. When a certain temperature value is exceeded, it turns off the device in order to avoid breakdowns and fires. Such systems are especially important for semiconductor types of stabilizers - thyristor and triac(see above). And in some models, this function can be supplemented by a temperature increase signal - it works at a temperature close to critical.

- From high-frequency interference. This protection dampens incoming high-frequency interference, preventing them from affecting the operation of devices connected to the stabilizer. Such interference can occur, for example, from electric motors, welding machines, etc. So, in audio systems, high-frequency distortion causes an unpleasant background from the speakers. RFI protection filters out these distortions, providing a smooth sine wave output.

- Against short circuit. A system that protects the stabilizer in the event of short circuits in the connected load. A short circuit is a situation when the resistance in the circuit becomes close to zero; this leads to a sharp increase in current strength, overloads the power grid and the stabilizer itself, and also creates a ri...sk of breakdown or even fire. In order to avoid unpleasant consequences, appropriate protection is provided: it disconnects the load in case of a significant excess of the current in it. This feature is almost mandatory in modern stabilizers.

- From overload. Safety system in case of stabilizer overload - that is, a situation when the total power of the connected load becomes greater than the corresponding indicators of the device itself (see "Power"). The reason for this situation may be, for example, the inclusion of an additional consumer or a change in the operating mode of one of the existing ones. Unlike the short circuit described above, when overloaded, all electrical appliances work normally, the stabilizer itself is abnormal, which can lead to its failure or even fire. To avoid this, overload protection is applied. Its specific implementation may be different. In some models, the load is turned off immediately, in others - after a certain time after the warning signal, which gives the user the opportunity to reduce power consumption and avoid system tripping.

- From over / under voltage. A system that protects the device from too low or too high input voltage. A significant overshoot of the input voltage range (see above) is dangerous not only by the risk of damage to the stabilizer itself: under such conditions, the device’s capabilities are not enough to fully protect the connected load, which can result in trouble for it. And this function prevents such consequences: if the input voltage goes beyond the permissible values (they may be wider than the operating values, see “Input voltage range”), the stabilizer is disconnected from the network. At the same time, some of its functions may remain operational - for example, a voltmeter that allows you to assess the "state of affairs" in the network at the input. And in some models there is a function to automatically turn on when the voltage returns to operating limits.
Luxeon EDC-1000 often compared