Comparison LG MA-12AH1 35 m² vs LG Artcool Gallery A-12AW1 35 m²

Add to comparison
LG MA-12AH1 35 m²
LG Artcool Gallery A-12AW1 35 m²
LG MA-12AH1 35 m²LG Artcool Gallery A-12AW1 35 m²
from $581.00
Outdated Product
from $1,012.67 up to $1,232.40
Outdated Product
TOP sellers
Typemulti split systemsplit system
Installationwallwall
Recommended room area35 m²35 m²
In box
 
 
indoor unit
outdoor unit
Number of indoor units1
Features
Modes and programs
cooling, heating, dehumidification, ventilation
automode
night mode
self-cleaning
cooling, heating, dehumidification, ventilation
automode
night mode
self-cleaning
Functions
inverter compressor
timer /24 hours/
auto restart
self-diagnosis
inverter compressor
timer /24 hours/
auto restart
self-diagnosis
Filters
plasma (electrostatic)
plasma (electrostatic)
Performance
Power consumption (cooling/heating)1090/1160 W
Cooling capacity3500 W3500 W
Heating capacity4200 W4200 W
Air flow600 m³/h600 m³/h
Dehumidification1.5 L/h1.5 L/h
Noise level (max/min)39/25 dB
39/25 dB /outdoor unit noise - 48 dB/
Refrigerant typeR410АR410А
Efficiency
Min. T for cooling mode-10 °C
Min. T for heating mode-10 °C
General specs
Maximum height difference between units7 m
Maximum pipe length15 m
Indoor unit dimensions (WxHxD)
600х600х145 mm /weight — 15 kg/
600х600х145 mm /weight — 15 kg/
Dimensions of window/outdoor unit (WxHxD)
770х540х245 mm /weight — 32 kg/
Color
Added to E-Catalogmay 2014april 2008

Type

General type of air conditioner.

Nowadays, on the market you can mainly find split systems, multi split systems, portable devices. More rare options are window models and monoblocks. Here is a more detailed description of each of these options:

— Split system. The most popular type of modern air conditioner. Such models consist of two units — indoor and outdoor. The outdoor unit is responsible for heat exchange with the environment — it is through it that excess heat is discharged (or vice versa, external heat is taken into the room, when working for heating). The indoor units are installed in the room, the conditioned air comes from it. Both units are connected by pipes through which the coolant circulates. Air conditioners of this type are convenient, in particular, because the indoor unit can be installed almost anywhere in the room; and in some models, the indoor units have an unusual design (see below), which allows such devices to fit even into non-standard interiors. Also note that split systems can have almost any performance, among them there are models of both household and industrial levels, and the installation of such air conditioners is relatively simple. All this led to their popularity.

— Multi split system. A kind of split system (see above), in which there are several indoor ones for one outdoor...unit. This arrangement allows using one air conditioner to organize climate control in several rooms at once, while the installation of such a system is easier, and the cost is cheaper than using separate split systems.

— Portable. Air conditioners made as a single unit, designed for the possibility of frequent movement from place to place; in some models, wheels are even provided for this. For heat exchange with the external environment, such devices use air ducts that lead out of a window, doorway, ventilation shaft, etc. A mobile air conditioner can be a real salvation where it is not possible to install a stationary device: it does not require complex installation work, just figure out where to bring the duct pipe. In addition, such a unit can be useful in a situation where you need to cool several rooms in turn, and it is difficult or impossible to install a stationary air conditioner for this purpose.

— Window. Air conditioners made as a single unit, installed directly in the window opening — so that one side of the device is indoors, the other is outdoors. It is one of the first types of air conditioners, but, nowadays, it is considered obsolete and rare — mainly due to the complexity of installation and a very limited choice of installation locations. In addition, such an assembly inevitably covers part of the window, which in some cases is also a serious drawback.

— Monoblock. Stationary air conditioners in the form of a single unit with wall installation. Such a unit is located inside the room, on the wall facing the outside, and heat exchange is provided by air ducts passed through the wall, through which the outside air enters the heat exchanger and exits it. Such a design allows you to do without outdoor units, which is very convenient in some situations — for example, if an air conditioner is needed for a historical building or house in a strictly defined design that does not allow unnecessary "decorations" on the facade. On the other hand, monoblocks are expensive, and the possibilities for their installation are very limited.

In box

A set of components included in the delivery of the air conditioner.

This parameter is indicated only for split and multi split systems (see "Type") — other types of air conditioners are made as single units, and there is simply no need to specify the complete set for them. Split system can be supplied both in a complete set, and in separate units (both indoor and outdoor). Among traditional split systems, the first option is the most popular: it is most convenient to buy such a solution as a ready-made kit, and the purchase of a separate unit is required if one of the original units breaks down. But the components of multi split air conditioners, on the contrary, are most often sold separately — this makes it easy to assemble such a system for a specific situation by separately purchasing an outdoor unit and the required number of indoor ones.

Number of indoor units

The number of indoor units supplied in the kit.

Split and multi split systems are divided into outdoor and indoor units (see "Type"). And the number of indoor units in the kit depends on how many rooms the air conditioner can serve out of the box. However, this parameter is more of a reference than practically significant. So, in a complete set (see "In box") split systems are supplied with one indoor unit. And in the multi split system, a complete set is rare and usually includes two such units; it is assumed that for the organization of a more extensive system, it is more convenient to purchase an outdoor unit and separately purchase the required number of indoor ones for it. Separate indoor units of multi split systems are also sold one by one.

Power consumption (cooling/heating)

Power consumption of the air conditioner in cooling and heating mode; for models without a heating mode, only one number is given. This parameter should not be confused with the effective capacity of the air conditioner. Effective capacity is the amount of heat that the unit can "pump" into the environment or the room. This item also indicates the amount of electricity consumed by the device from the network.

In all air conditioners, the power consumption is several times lower than the effective capacity. It is due to the peculiarities of the operation of such units. At the same time, devices with the same efficiency may differ in power consumption. In such cases, the more economical models usually cost more, but with continued use, the difference can quickly pay off with less electricity consumption.

Also, two points related to electrical engineering depend on this nuance. Firstly, power consumption affects power requirements: models up to 3 – 3.5 kW can be connected to a regular outlet, while higher power consumption requires a three-phase connection (see below). Secondly, the power consumption is needed to calculate the load on the mains and the necessary parameters of additional equipment: stabilizers, emergency generators, uninterruptible power supplies, etc.

Min. T for cooling mode

The lowest outdoor air temperature at which the air conditioner can operate normally in cooling mode.

The need for air cooling arises not only in hot weather — for example, efficient heat dissipation is constantly needed in closed rooms with a lot of heat-generating equipment (such as server rooms). And the limitation on the minimum outdoor temperature is because a large temperature difference between the condenser (heater) of the outdoor unit and the environment can damage the circuits.

Note that in domestic air conditioners, this limit can be quite high — +20 °С and even higher (up to +25 °С); however, additional cooling is usually required for warmer weather, and such air temperatures are not so high as to cause significant discomfort. But in professional units, the minimum temperature for the cooling mode can be significantly below zero — up to -40 °C and even lower.

It is also worth mentioning that in the presence of a heating mode, the permissible temperature for it is noticeably lower than for the cooling mode. It is due to the difference between the formats of the air conditioner in these modes.

Min. T for heating mode

The lowest outdoor temperature at which the air conditioner can operate normally in heating mode.

Modern air conditioners with heating mode are quite cold-resistant appliances. Thus, models where this temperature limit exceeds 0 °C are rare. A lot of units, even quite inexpensive ones, have a minimum temperature allowed for heating in the range of -5 ... -10 °C or -11 ... -15 °C. Models with indicators of -16 ... -20 °C and -21 ... -25 °C, although much less, are still quite a few, and air conditioners capable of heating at -25 °C and below are very close in terms of capabilities to heat pumps.

Maximum height difference between units

The maximum height difference allowed for split system units. For multi splits (see "Type"), in this case, we mean the difference in height between the highest and lowest unit.

When installing units at different heights, a pressure difference arises in the system — the greater the height difference, the greater this difference, and if it is too large, the system will not be able to work normally.

Maximum pipe length

The maximum allowable length of the refrigerant pipes connecting the outdoor and indoor unit of a split or multi split system (see "Type"). The length of the tubes is implied in one direction, from the indoor unit to the outdoor unit (or vice versa).

In most modern air conditioners, this parameter is about 15 – 20 m or even more, so problems with the maximum length can only arise if the units are far from each other. It is technically possible to use tubes longer than the maximum allowed, but this will affect the efficiency of the air conditioner and may require refilling the freon.