DC Miniature 1P 125A 250V DIN Rail Mount for Solar PV System TOB1Z 125 C1258.93Buy!£Joom UKDelivery: to United Kingdom ReportFeature: 1. HOME OR COMMERCIAL USE: Widely used for solar panel grid connected system, wind solar complementary system and other DC circuit system to avoid overcurrent damage caused by overload or sho more→rt circuit. Can also be used for household 240V circuit on and off use 2. ARC EXTINCTION: DC arc extinguishing is more difficult than AC, this DC circuit breaker has an auxiliary arc extinguishing magnetic system, which is more fast 3. MAIN APPLICATION: Suitable for solar system, battery, UPS, inverter, mains, DC power supply system, Marine power system, solar photovoltaic system or other DC system. Mainly used for overload protection and short circuit protection 4. ISOLATION AND PROTECTION FUNCTION: …
SEG?125 DC 230V 125A 1P Dual Power Isolation Switch for Solar and Power Generation11.72Buy!£Joom UKDelivery: to United Kingdom ReportFeature: 1. Protect Circuits: DC switch is used to protect circuits from overcurrent damage caused by overloads or short circuits, and quick release ensures reliable operation of the load and extends more→the service life of the electrical circuit breaker. It can also act as a switch for DC load circuits. 2. Main Purpose: The solar isolator switch is used in a separate enclosure with fuse holder (125A) and surge guard. The dual power supply can be used to switch between generator and mains power or between solar power and mains power. 3. Safe to Use: The power disconnect switch has better synchronization when opening and closing. Six rivets riveted, riveted firmly to avoid shell cracking after wiring.…
DC Circuit Breaker Short Circuit Protection Rail Installation PV Circuit Breaker 2P 1000V 125A Red12.38Buy!£Joom UKDelivery: to United Kingdom ReportFeature: 1. Main Function: This circuit breaker is used to defend power distribution facilities from overload and short circuit damage, and can also be used for control and isolation. 2. Fast Tripping more→: The electromagnetic tripping system of this circuit breaker can trip immediately in case of short circuit to defend circuit safety. 3. Arc Extinguishing: DC arc extinguishing is more difficult than AC arc extinguishing. The DC circuit breaker has a magnetic system for auxiliary arc extinguishing. 4. Wide Application: This circuit breaker can be used for DC power supply system, ship power system, solar photovoltaic system or other DC systems. 5. Rail Installation: This circuit breaker features …
4P Automatic Transfer Switch 35mm Rail Mount Dual Power Generator Changeover Switch AC400V 125A30.00Buy!£Joom UKDelivery: to United Kingdom ReportFeature: 1. MAIN PURPOSE: A miniature household power switch, mainly used to test whether the main power supply or standby power supply is normal to ensure power continuity, reliability and security. more→2. OPERATION METHOD: The dual power switch supports manual and automatic operation, millisecond switching without power failure, reliable transmission, easy installation and maintenance. 3. 35MM RAIL MOUNT: The automatic transfer switch adopts 35mm standard guide rail installation method, suitable for PZ30 distribution boxes, with a compact structure, and takes less space. 4. DURABLE MATERIAL: The switch shell is made of PC flame retardant plastic, with good insulation, high temperature and aging …
Schneider Electric Schneider C120N 3P 125A Circuit Breaker 10kA - A9N18369 A9N18369249.46Buy!£Tameson.co.ukDelivery: in United Kingdom ReportLow voltage miniature circuit breaker (MCB) with 3-pole protection and C-characteristic trip curve. Rated for 125A nominal current with 10kA breaking capacity at 380-415VAC (IEC 60947-2). Features dua more→l compliance with domestic (IEC 60898-1) and industrial (IEC 60947-2) standards. Includes visual position indicator with green strip for quick status identification. Mechanical lifetime of 20,000 cycles and electrical lifetime of 5,000 cycles.
Schneider Electric Schneider Electric C120N 4P 125A Circuit Breaker 10kA - A9N18355 A9N18355342.33Buy!£Tameson.co.ukDelivery: in United Kingdom ReportLow voltage miniature circuit breaker (MCB) with 4 protected poles and B-characteristic tripping curve. Features 125A nominal current and 10kA breaking capacity at 380-415V AC (IEC 60947-2). Compliant more→with both household (IEC 60898-1) and industrial (IEC 60947-2) standards. Includes visible green strip indicator for OFF position and offers 20,000 mechanical and 5,000 electrical operation cycles.
EATON INDUSTRIES Eaton NS1 Molded Case Switch 3P 125A Max Protection 1250A UL IEC - 102683 102683386.99Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries molded case switch-disconnector is a 3-pole, N1 type switch with a rated current of 125 A and a switching capacity SCCR of 480Y/277 V at 60 Hz with an Icu of 35kA. This unit also more→operates as a main switch with a disconnecting function. Designed for fixed installation, it features a box terminal. The device meets UL/CSA and IEC standards, denoting its high level of safety and performance. Rated current equals uninterrupted current, represented as In equals Iu.
EATON INDUSTRIES Eaton NZMB1-AF125-NA Circuit Breaker 3P 125A 25KA UL IEC - 281558 281558388.17Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries MCCB Circuit-breaker NZM1 is a 3 pole system designed for fixed installations. It has a switching capacity SCCR of 480Y/277 V at 60 Hz, with a rated uninterrupted current (In = Iu more→) of 125 A. This circuit breaker features a box terminal and is aligned with UL/CSA and IEC standards. It offers system and cable protection functions as part of its protective features, making it a reliable choice for system security and safety.
EATON INDUSTRIES Eaton Circuit Breaker 3P 125A 25KA UL IEC - 269166 269166388.29Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries MCCB is a 3-pole circuit-breaker compatible with NZM2. Its switching capacities are as follows: SCCR 480Y/277V 60Hz with an interrupting capacity (Icu) of 25 kA; SCCR 600Y/347V 60 more→Hz with an Icu of 18 kA, and SCCR 480V 60Hz with an Icu of 25 kA. The breaker has a rated current and rated uninterrupted current (In = Iu) of 125 A. Designed for fixed installation, it uses screw connections. The breaker is standard approved by UL/CSA and IEC and serves the protective function of system and cable protection.
EATON INDUSTRIES Eaton AZ-4-C125 4-Pole MCB Circuit Breaker 125A - 211812 211812405.23Buy!£Tameson.co.ukDelivery: in United Kingdom ReportIndustrial-grade 4-pole miniature circuit breaker with C-characteristic tripping curve and 125A rated current. Features 25kA breaking capacity according to IEC 60947-2 and 15kA to EN 60898. Designed f more→or 400V AC systems with IP20 protection rating and 75mm mounting depth. Suitable for advanced commercial and industrial applications.
EATON INDUSTRIES Eaton Circuit-Breaker NZMB2-A125 NZM2 3P 125A 25KA - 259087 259087406.82Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZMB A is a circuit-breaker designed according to IEC/EN60947-2 standards. It features screw connections and screw fixing, with a Ui of 690V and a degree of protection of IP20. Th more→e device is finger proof as per VDE 0106 T. 100. It comes with an adjustable overload release Ir ranging from 0.8 to 1 x In. The short-circuit release Ii is adjustable, ranging from 6 to 10 x In and there is a permanently set short-circuit release Ii as a limitation. The unit's nominal continuous current Iu is 125A and the nominal voltage is 440V. Its nominal cut-off capacity at Icu at 400 is 25kA. The overload protection setting range is 100-125A, while the instantaneous short circuit setting range …
EATON INDUSTRIES Eaton Circuit Breaker NZM1 3P 125A 36KA IEC - 271397 271397468.70Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries MCCB Circuit-breaker NZM1 is a three pole, fixed installation type device suitable for system and cable protection. It has a switching capacity of 400/415 V 50 Hz with an interrup more→ting capacity (Icu) of 36 kA and a rated current, also known as the rated uninterrupted current (In = Iu), of 125 A. The breaker features box terminal and complies with the IEC standards.
EATON INDUSTRIES Eaton NZM2 Circuit Breaker 4P 125A 25KA IEC - 265847 265847472.71Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZMB A is a circuit-breaker functioning in compliance with IEC/EN60947-2 standards. Its nominal continuous current Iu is 125A, with a nominal voltage of 440V and a nominal breakin more→g capacity Icu at 400 25kA. The circuit-breaker includes an adjustable overload protection setting range from 100 - 125A and an undelayed short circuit setting range from 6 - 10A. It comes with screw connections and screw fixing in a built-in device fixed installation form. It operates at Ui 690V with a degree of protection IP20 and is finger proof according to VDE 0106 T. 100 standards. The overload release setting Ir is adjustable between 0.8 - 1 × In, short-circuit release Ii is adjustable between 6…
EATON INDUSTRIES Eaton NZMC2-A125 Circuit Breaker 3P 125A 36KA IEC - 271420 271420479.74Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries MCCB (Molded Case Circuit Breaker) belongs to the NZM series, which covers all application cases with just four compact sizes. This makes it highly suitable for the IEC (Internati more→onal Electrotechnical Commission) market. Its installation is designed to be flexible, with the capacity to utilize modular function groups. This allows for increased adaptability and convenience during setup and operation.
EATON INDUSTRIES Eaton Circuit Breaker 4P 125A 25KA Box Terminals - 113011 113011480.23Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries MCCB circuit-breaker, with a nominal continuous current Iu of 125A and nominal voltage of 440V, offers a nominal cut-off capacity Icu of 25kA at 400. The overload protection setti more→ng range is 125A, while the short-delay setting range is 750 - 1250A, and the undelayed short circuit setting range is 6 - 10A. This Series NZM..-AF..NA circuit-breaker comes in four compact sizes, covering all application cases and is ideal for international markets. It features modular function groups for flexible mounting and thermomagnetic releases for systems and cable protection. It has fixed overload releases, complies with UL/CSA and IEC regulations, and features IEC switching performance …
EATON INDUSTRIES Eaton 3P 125A Circuit Breaker NZMB2-M125 - 265715 265715495.55Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZMB M power circuit-breaker, with a nominal continuous current Iu of 125A and a nominal switch-off capacity Icu at 400 53kA, covers all applications with only four compact sizes, more→suitable for the IEC market. It includes an adjustable range for overload protection from 960 - 1600A and adjustable range for instantaneous short circuit from 960 - 1600A. Its main circuit connection method is screw connection, with three poles. It is adaptable due to the modular function groups and features thermomagnetic release for motor protection. This complies with tripping class 10A, IEC/EN 60947-4-1, and IEC/EN 60947-2 circuit-breakers meet all requirements of the switching category AC-3.…
EATON INDUSTRIES Eaton NZMB2-A125-NA NZM2 Circuit Breaker 3P 125A 25KA UL/IEC - 269214 269214495.76Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZMB A is a 3-pole circuit-breaker with a rated uninterrupted current (In=Iu) of 125A. It features a switching capacity SCCR of 25 kA at 480Y/277 V 60 Hz, 18 kA at 600Y/347 V 60 H more→z, and 25 kA at 480 V 60 Hz. The device is designed for system and cable protection. Additionally, it offers an overload protection setting range of 100 - 125A, and an instantaneous short circuit setting range of 750 - 1250A. The Eaton NZMB A circuit breaker has a fixed installation type with a screw connection. It follows UL/CSA, IEC standards, ensuring optimal performance and reliability.
EATON INDUSTRIES Eaton Circuit Breaker NZM1 3P 125A UL IEC 25kA - 281562 281562500.90Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries 3-pole NZM1 circuit breaker offers a switching capacity SCCR of 480Y/277 V 60 Hz, with an interrupting capacity (Icu) of 25 kA. It has a rated current equal to its rated uninterru more→pted current (In = Iu) of 125 A. This unit is designed for fixed installation and features a box terminal. It adheres to UL/CSA, IEC standards and provides system and cable protection.
EATON INDUSTRIES Eaton Circuit Breaker 3 Pole 125A 50KA NZMN2-A125 IEC - 259091 259091501.54Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZMN A is a circuit breaker with three poles, featuring a rated uninterrupted current of 125A. It has a switching capacity of 400/415V 50 Hz with an interrupting capacity (Icu) of more→50kA. It is designed for fixed installation and is connected via screw connection. The device complies with IEC standards. Its protective function pertains to system and cable protection. It has an overload protection setting range of 100 - 125A and an immediate short-circuit setting range of 750 - 1250A. The breaker offers a nominal voltage of 690V.
EATON INDUSTRIES Eaton NZMN1-A125 3-Pole 125A 50kA Circuit Breaker - 259086 259086506.59Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZMN A circuit-breaker is a 3-pole device with a rated uninterrupted current of 125A and a rated voltage of 690V. The item's switching capacity at 400/415V 50Hz (Icu) is 50kA. It more→has adjustable ranges for overload protection from 100-125A and for undelayed short-circuit from 750-1250A. This circuit-breaker is suitable for system and cable protection according to IEC standards. The device can be installed as a fixed, built-in device and comes with a box terminal for ease of installation.
EATON INDUSTRIES Eaton NZMN2-S125 3P Circuit Breaker 125A 50KA IEC - 265739 265739534.30Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZMN S circuit breaker comes in four compact sizes, covering all application scenarios. It has a nominal continuous current Iu of 125A and a nominal cut-off capacity Icu of 53kA a more→t 400. The overload protection range is from 960 - 1600A, and the non-delayed short circuit setting range is also from 960 - 1600A. The main circuit connection method is via screw connection and it has 3 poles. The breaker is designed to be highly flexible in mounting, featuring a magnetic short-circuit release associated with the overload relay. Additionally, it is designed to operate without an overload trip. The product meets all requirements of the switching category AC-3.
EATON INDUSTRIES Eaton Circuit Breaker NZM1 4P 125A 36KA IEC - 271418 271418546.86Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries MCCB Circuit Breaker NZM1 is a 4-pole device with a switching capacity of 400/415 V at 50 Hz. Its rated current and rated uninterrupted current (In = Iu) are both 125 A. It is des more→igned for fixed installation and comes with a box terminal. It adheres to the IEC standards, ensuring quality and reliability. The circuit breaker also has a protective function that safeguards the system and cable.
EATON INDUSTRIES Eaton NZM2 Circuit Breaker 3P 125A 50KA Box Terminals - 174617 174617548.41Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries MCCB Power Circuit Breaker is a standard equipment with a box terminal. It operates at a switching capacity of 400/415V at 50 Hz. With an interrupting rating (Icu) of 50 kA, this more→circuit breaker can handle a nominal current (In) equal to the uninterrupted current (Iu) up to 125 A. This system is therefore designed for high-capacity operations and ensures hassle-free performance even under rigorous power conditions.
EATON INDUSTRIES Eaton Circuit Breaker NZMH1-A125 3P 125A 100KA IEC - 284414 284414575.37Buy!£Tameson.co.ukDelivery: in United Kingdom ReportThe Eaton Industries NZM1 circuit-breaker is a 3-pole device with a switching capacity of 100 kA at 400/415 V 50 Hz (Icu). It operates with rated current and uninterrupted current (In = Iu) of 125 A. more→This robust device is designed for fixed installations and connects via a box terminal. Compliant with IEC standards, the circuit-breaker provides vital system and cable protection. The overload protection setting range is 100 - 125A, while the un-delayed short circuit setting range is 750 - 1250A. This device is also designed with a nominal voltage of 690V and a nominal cut-off capacity at 400 50kA.