The Eaton Industries Molded Case Switch is designed with a switching capacity of SCCR 480Y/277V 60Hz Icu of 100 kA and a SCCR 600Y/347V 60Hz Icu of 50 kA. Boasting a rated current as well as a rated u more→ninterrupted current of 160 A, it provides efficient and reliable operation. Suitable for fixed installations, it comes with a screw connection. This switch-disconnector is a 3-pole type, providing maximum protection as required by disconnectors or main switches. It adheres to UL/CSA and IEC standards, ensuring quality and safety.
437.90Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB power switch is a molded case switch with switch-disconnectors and 3 poles, designed for reliable operation under substantial loads. It features a switching capacity of SCCR more→480Y/277 V 60 Hz with an Icu of 100 kA, and a SCCR 600Y/347 V 60 Hz with an Icu of 50 kA. Both the rated and uninterrupted currents are identical, set at 160 A. This power switch satisfies standards of UL/CSA and IEC. It is a fixed installation type and comes with a box terminal. Its main protective function is as a switch-disconnector or a main switch.
450.91Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMB A is a 3-pole circuit-breaker with a rated uninterrupted current (In = Iu) of 160A and a nominal voltage of 440V. Its switching capacity at 400/415V 50Hz ( Icu ) is 25kA. The more→device is designed for system and cable protection and is set in a fixed installation type with a box terminal. It offers an overload protection setting range of 125 - 160A and an undelayed short circuit setting range of 960 - 1600A. This product complies with IEC standards.
456.60Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMB A is a three-pole circuit breaker designed for system and cable protection. With a rated current and rated uninterrupted current (In = Iu) of 160A, this device exhibits switc more→hing capacity at 400/415V 50Hz (Icu) of 25kA. The circuit breaker has an adjustable overload protection range from 125 - 160A and an adjustable instantaneous short circuit range from 960 - 1600A. The device is designed for fixed installation, featuring a screw connection. It meets IEC standard and approval.
471.90Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMB S circuit-breaker is suitable for continuous operation with a nominal current of 160A. It boasts a nominal cut-off power of Icu at 400 53kA and overload protection settings r more→anging from 1210 to 2000A. Similarly, the short-circuit setting range is between 1210 to 2000A. This circuit-breaker features a screw connection for the main circuit and has three poles. Moreover, it comes equipped with magnetic short-circuit release paired with an overload relay and allows short-circuit release without overload tripping. It is worth noting that this circuit-breaker meets all requirements of the AC-3 switching category. Only four compact sizes are available, but modular function …
486.05Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB circuit-breaker NZM2 features a 3-pole design with a switching capacity of 400/415 V 50 Hz. It has an interrupting capacity (Icu) of 25 kA and operates with a rated current, more→equivalent to its rated uninterrupted current (In = Iu), of 160 A. This circuit-breaker is designed for fixed installation type and is equipped with box terminal. Compliant with IEC standards, it serves a protective function geared towards system and cable protection.
514.64Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries Circuit-breaker NZM2, a three-pole MCCB power switch, operates with a switching capacity of 400/415 V 50 Hz and features an interrupting capacity (Icu) of 36 kA. The rated current more→, also known as the rated uninterrupted current (In = Iu), is 160 A. Specifically designed as a fixed installation type, it utilizes a screw connection method. According to IEC standards, this circuit-breaker serves a protective role, safeguarding both the system and the cables attached to it.
519.23Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMB A is a 4-pole circuit-breaker with a rated uninterrupted current (In = Iu) of 160A and a nominal voltage of 440V. It features an impressive nominal cut-off capacity (Icu) of more→25kA at 400/415V, 50Hz. The device provides a range of settings for overload protection from 125 to 160A and for instantaneous short circuiting from 6 to 10A. This model is designed in a fixed installation type with a screw connection. Compliant with IEC standards, it primarily serves system and cable protection functions.
519.98Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB Circuit-breaker NZM1 is a 3-pole power switch with a switching capacity of 400/415 V 50 Hz and an interrupting capacity (Icu) of 36 kA. Its rated current, also known as the r more→ated uninterrupted current (In = Iu), is 160 A. The unit is designed for fixed installations and features a box terminal. It meets the standards and approvals set by the IEC. The primary protective function of this circuit breaker is for system and cable protection.
525.62Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMB M is a power circuit-breaker with a continuous nominal current (Iu) of 160A and a nominal cut-off power (Icu) of 53kA at 400. It features an overload protection setting range more→of 1210 - 2000A and an un-delayed short circuit setting range of 1210 - 2000A. The main current circuit connection method is a screw connection and the breaker is three poles. It belongs to the NZM..-M series which is suitable for all applications in the IEC market in four compact sizes, with a modular function group allowing flexible mounting. It features thermomagnetic release for motor protection, meets the requirements of switching category AC-3 and complies with IEC/EN 60947-4-1 and IEC/EN …
551.95Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMN A is a circuit-breaker with 3 poles, having a rated uninterrupted current (In = Iu) of 160A and a nominal voltage of 690V. Its switching capacity at 400/415 V 50 Hz (Icu) sta more→nds at 50 kA. The device is a fixed installation type with a screw connection and has several protective functions encompassing system and cable protection. It also holds the standard or approval from the IEC. The range for overload protection settings is 125 - 160A and the un-delayed short circuit setting range is between 960 - 1600A.
556.91Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZM1 is a 3-pole circuit-breaker featuring a rated uninterrupted current and rated current (In = Iu) of 160 A. It possesses a substantial switching capacity at 400/415 V 50 Hz wit more→h an Icu of 50 kA. This device provides a significant range of overload protection settings between 125 - 160A and undelayed short circuit settings from 960 - 1600A. With a fixed installation type and a box terminal structure, it conforms to the IEC standards. The key protective functions of this circuit-breaker include system and cable protection, making it ideal for various applications.
597.12Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMN S is a power circuit breaker suitable for the IEC market, with a rated continuous current Iu of 160A and a nominal breaking capacity Icu of 53kA at 400V. It features an overl more→oad protection adjustment range of 1210 - 2000A, and an instantaneous short-circuit release adjustment range of 1210 - 2000A. It utilises a screw connection for the main circuit and is a three-pole device. Flexibility in installation is provided by modular function groups. This breaker is equipped with a magnetic short-circuit release in conjunction with an overload relay and can actuate a short-circuit release without overload trip. Additionally, it adheres to all requirements of the AC-3 switching …
603.01Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB is a four-pole circuit-breaker, specifically the NZM2 model. It has a switching capacity of 400/415 V 50 Hz, with an interrupting capacity (Icu) of 36 kA. The rated current, more→which is the same as the rated uninterrupted current (In = Iu), is 160 A. The MCCB is designed for fixed installations and features a screw connection. It complies with the IEC standard, offering protection for both systems and cables.
608.86Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB Circuit-breaker NZM2 features three poles and a switching capacity of 400/415 V 50 Hz with an interrupting capacity (Icu) of 50 kA. The rated current, also known as the rated more→uninterrupted current (In = Iu), is 160 A. It's designed for fixed installation and uses a box terminal. This device complies with IEC standards and is primarily used for system and cable protection.
617.88Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB power switch, also known as a circuit-breaker NZM1, comes with 4 poles and has a switching capacity of 400/415 V at 50 Hz with an Icu of 36 kA. Its rated current is the same more→as its rated uninterrupted current, both measuring In = Iu at 160 A. It is designed as a fixed installation type with a box terminal. Additionally, it adheres to the standard/approval of the IEC. Its main protective function is providing system and cable protection.
648.19Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB circuit-breaker NZM1 is a durable, quality tested product designed to ensure optimal system and cable protection. The three-pole device features a rated uninterrupted current more→of 160 A, with a switching capacity at 400/415 V and 50 Hz of 100 kA. The overload protection adjustment range is between 125 - 160A, and the unimpeded short circuit's adjustment range is 960 - 1600A. Its standard approval is IEC and is a fixed, box terminal installation type. The product is most suitable for a setup with a nominal voltage of up to 690V and a nominal breaking capacity of Icu at 400 and 50kA.
662.34Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMN is a 4-pole circuit-breaker with a rated uninterrupted current (In = Iu) of 160A and a nominal voltage of 690V. This device features a switching capacity at 400/415V 50Hz (Ic more→u) of 50kA. The overload protection setting range is between 125 - 160A while the instantaneous short-circuit range is set between 6 - 10A. This circuit-breaker is designed for fixed inbuilt installation with a screw connection. It adheres to the IEC standard and provides both system and cable protection.
668.98Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZM1 circuit breaker is a fixed installation device rated for 160A of uninterrupted current. It features a 4-pole design with a switching capacity of 400/415V 50Hz, offering an in more→terrupting capacity (Icu) of 50 kA. The device is set to handle an overload protection range of 125 - 160A and an instantaneous short circuit setting of 1280A. This circuit breaker also meets IEC standards and is designed to provide both system and cable protection.
685.91Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMB A is a circuit-breaker with a switching capacity SCCR of 25 kA at 480Y/277 V 60 Hz, 18 kA at 600Y/347 V 60 Hz, and 25 kA at 480 V 60 Hz. It has a rated uninterrupted current more→of 160 A with an overload protection setting range of 125 - 160A and an instantaneous short circuit setting range of 960 - 1600 A. The device has a fixed built-in design and is installed through a screw connection. This breaker is approved by UL/CSA, IEC standards and is built specifically for system and cable protection.
687.78Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries NZMN M is a high-performance circuit breaker with a nominal continuous current Iu of 160A and a nominal breaking capacity Icu of 105kA at 400. Featuring a range of overload protec more→tion settings from 1210 - 2000A, as well as undelayed short circuit settings in the same range, this device ensures the safety of your electrical system. With a screw connection method for the main current circuit, it is designed with 3 poles. Its compact size is suitable for all applications in the IEC market. Following the thermomagnetic release, the circuit breakers meet all requirements of switching category AC-3, adhering to IEC/EN 60947-4-1 and IEC/EN 60947-2 standards. Tripping class is 10A …
706.32Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB circuit-breaker NZM2 features a three-pole design with a switching capacity of 400/415 V 50 Hz and an interrupting capacity (Icu) of 150 kA. The rated current, which is also more→the rated uninterrupted current (In = Iu), is 160 A. This circuit breaker is designed for fixed installation and comes with a box terminal. It complies with the IEC standards and offers system and cable protection as its primary protective function.
732.06Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB power circuit-breaker, model NZM2, boasts a 4-pole design with a switching capacity of both 400 and 415 V and a frequency of 50 Hz. The circuit breaker has an Icu of 50 kA an more→d a rated current equal to rated uninterrupted current (In = Iu) of 160 A. Its installation type is fixed, and it features a box terminal. The product complies with IEC standards and is designed to offer system and cable protection, ensuring safety and efficiency in your systems.
743.70Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries MCCB Circuit-breaker NZM2 features a 3 pole design with a switching capacity SCCR of 25 kA at 480Y/277 V 60 Hz, 18 kA at 600Y/347 V 60 Hz, and 25 kA at 480 V 60 Hz. Its rated curr more→ent matches its rated uninterrupted current at 160 A. This unit is designed for fixed installation and utilizes a box terminal. It holds standard approvals from UL/CSA and IEC. Notably, it provides system and cable protection, aligning well with engineering safety standards.