Catalog   /   Home & Renovation   /   Electrical Equipment   /   Circuit Breakers

Circuit Breakers

 prices on 1554 models
Show
59.79Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Eaton Industries Xpole motor-protective circuit-breaker is designed with thermal overload release and magnetic short-circuit release, suitable for switching and protecting three-phase motors with more→power outputs up to 15kW (380/400V), or other loads carrying currents up to 40A. It can also function as a main switch. Its isolating features are compliant with IEC/EN 60947 standard. The unit has a contact position display that is color-coded with red/green for easy reference.
60.29Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
This easy-to-use FAZ installation circuit breaker features window and elevator terminals at the top and bottom. Thanks to contact position indicators (CPI), you always know the status of the contacts. more→The 3-position DIN-rail clip allows removal from existing busbar. Eaton Moeller FAZ circuit breakers are available in several variants.
60.42Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electrom more→echanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications.
60.46Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electrom more→echanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications.
60.78Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Low voltage miniature circuit breaker with 3-pole plus neutral protection, rated at 6A with C-curve tripping characteristic. Features 4500A breaking capacity at 400VAC (IEC 60898-1) and 6kA at 400VAC more→(IEC 60947-2). Designed for both residential and industrial applications with clip-on installation. Offers 20,000 cycle electrical and mechanical lifespan with 400VAC operational voltage rating.
61.37Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
This iC60N circuit breaker has a visi-trip window. This signaling of shutdown due to a fault by a red mechanical status indicator is on the front of the automaton. The green strip on the switch of the more→Acti 9 iC60 circuit breaker ensures that the contacts are physically open and that work can be performed on the downstream circuit in complete safety. In addition, this Schneider Electric circuit breaker features a double clip for disassembly while the comb rail is still in place.
61.50Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electrome more→chanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications.
61.59Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Three-pole motor circuit breaker with thermal-magnetic protection, rated for 10A/690V operation and suitable for 3-phase motor applications from 3 to 4kW at 400V. Features 100kA breaking capacity at 4 more→00V, screw terminal connections, and 100,000 cycle mechanical/electrical durability. IP20 protection rating with multi-standard certification including IEC, UL, CSA, CCC, EAC, Marine, and ATEX.
61.66Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electrome more→chanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications.
61.70Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
SMISSLINE TP S400M are a current limiting miniature circuit breakers. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechani more→c tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K), configurations (1P,1P+N,2P,3P,3P+N), breaking capacities (up to 10 kA at 240/415 V AC ) and rated currents (up to 63A). MCBs of the product range S400M are comply with IEC/EN 60898-1 for B,C and D characteristic and IEC/EN 60947-2 for C and K characteristic.
61.97Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
This iC60N circuit breaker has a visi-trip window. This signaling of shutdown due to a fault by a red mechanical status indicator is on the front of the automaton. The green strip on the switch of the more→Acti 9 iC60 circuit breaker ensures that the contacts are physically open and that work can be performed on the downstream circuit in complete safety. In addition, this Schneider Electric circuit breaker features a double clip for disassembly while the comb rail is still in place.
61.98Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
This iC60N circuit breaker has a visi-trip window. This signaling of shutdown due to a fault by a red mechanical status indicator is on the front of the automaton. The green strip on the switch of the more→Acti 9 iC60 circuit breaker ensures that the contacts are physically open and that work can be performed on the downstream circuit in complete safety. In addition, this Schneider Electric circuit breaker features a double clip for disassembly while the comb rail is still in place.
62.05Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Low voltage miniature circuit breaker with 3-pole plus neutral protection, rated at 25A with C-curve tripping characteristics. Features 4500A breaking capacity at 400VAC (IEC 60898-1) and 6kA at 400VA more→C (IEC 60947-2). Designed for both residential and industrial applications, protecting circuits against short circuits and overload currents. Includes clip-on mounting for easy installation.
62.43Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Schneider electric acti9 i60n mcbs 2 pole. Acti 9 ic60n series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload current more→s it also protects people against indirect contact with tn and it neutral systems. Fully compliant with standards iec/en 60898 and iec/en 60947-2. Acti 9 is fully tested, approved and certified by national and international third parties.
62.44Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Schneider electric acti9 i60n mcbs 2 pole. Acti 9 ic60n series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload current more→s it also protects people against indirect contact with tn and it neutral systems. Fully compliant with standards iec/en 60898 and iec/en 60947-2. Acti 9 is fully tested, approved and certified by national and international third parties.
62.51Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
This easy-to-use FAZ installation circuit breaker features window and elevator terminals at the top and bottom. Thanks to contact position indicators (CPI), you always know the status of the contacts. more→The 3-position DIN-rail clip allows removal from existing busbar. Eaton Moeller FAZ circuit breakers are available in several variants.
62.63Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
3-pole motor protection circuit breaker with adjustable overload and short-circuit protection. Features phase failure sensitivity, 690V rated operating voltage, and IP20 protection rating. Compatible more→with screw and snap fitting installation, with 45mm cap dimension. Meets IEC/EN60947 standards with VDE 0106 T.100 finger-proof design. Supports auxiliary contact and voltage release accessories.
24 more item(s)