Three-phase motor circuit breaker with thermal-magnetic protection for 15kW@400V applications. Features adjustable thermal range of 23-32A, magnetic trip at 14xIn, and high breaking capacity of 100kA@ more→400V. Includes Everlink BTR screw terminals, 50,000 cycle rotary handle operation, and IP20 protection. Certified to multiple standards including IEC, UL, CSA, and ATEX. Operating temperature range: -20°C to +60°C.
152.42Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Schneider electric acti9 ic60l mcbs 1 pole. Acti 9 schneider ic60l series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overl more→oad currents it also protects people against indirect contact with tn and it neutral systems. Fully compliant with standards iec/en 60898 and iec/en 60947-2. Acti 9 is fully tested, approved and certified by national and international third parties.
153.56Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
This easy-to-use FAZ installation circuit breaker features window and elevator terminals at the top and bottom. Thanks to contact position indicators (CPI), you always know the status of the contacts. more→The 3-position DIN-rail clip allows removal from existing busbar. Eaton Moeller FAZ circuit breakers are available in several variants.
154.25Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Socket rail fork 4-pole 16 mm² 56 modules. In combination with quickbusbar components, the installation-friendly quickbusbar rails (KDN) provide a quick, secure and screwless connection. This Quickbus more→bar connection rail is for the purpose of 14 circuit breakers or earth leakage switches 4p. The Hager Quickbusbar comb rails are available in different variants.
154.59Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Three-pole magnetic motor circuit breaker rated at 50A/690V, designed for 22kW@400V three-phase motor applications. Features magnetic protection with 14xIn trip level and high breaking capacity of 50k more→A@400V. Equipped with Everlink BTR screw terminals and rotary control rated for 50,000 AC-3 cycles. Compatible with LRD350 thermal overload relay for complete motor protection.
156.26Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electrome more→chanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications.
157.99Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Legrand TX3 circuit breaker can be connected with either pin or fork terminal rails. In addition, this Legrand circuit breaker can be equipped with DX3 auxiliary contacts. The TX3 circuit breaker more→cannot be equipped with ground fault elements. Legrand Lexic TX3 circuit breakers are available in different variants.
158.65Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Legrand DX3 circuit breaker can be connected with either pin or fork terminal rails. Short circuit breaking capacity according to IEC 60947-2 - 10kA. In addition, this Legrand circuit breaker can more→be equipped with DX3 auxiliary contacts. The DX3 circuit breaker cannot be fitted with ground fault elements. Legrand Lexic DX3 circuit breakers are available in different variants.
159.73Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Schneider electric acti9 ic60l mcbs 1 pole. Acti 9 schneider ic60l series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overl more→oad currents it also protects people against indirect contact with tn and it neutral systems. Fully compliant with standards iec/en 60898 and iec/en 60947-2. Acti 9 is fully tested, approved and certified by national and international third parties.
160.39Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Socket rail fork 2-pole 16 mm² 56 modules. In combination with quickbusbar components, the installation-friendly quickbusbar rails (KDN) provide a quick, secure and screwless connection. This Quickbus more→bar connection rail is for the purpose of 28 circuit breakers, earth leakage switches or earth leakage circuit breakers 2p. The Hager Quickbusbar comb rails are available in different variants.
160.46Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Three-pole magnetic motor circuit breaker rated at 65A/690V, designed for 30kW@400V three-phase motor applications. Features magnetic protection with 14xIn trip level and 50kA@400V breaking capacity. more→Equipped with Everlink BTR screw terminals and 3-position lockable rotary control rated for 50,000 AC-3 cycles. Requires LRD365 thermal overload relay for complete motor protection. Compliant with IEC, CCC, EAC, Marine standards.
161.05Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
Doepke circuit breaker, tripping characteristic C, co-switching neutral, nom. (measuring) current 32A, voltage type AC, 4 poles (total), width in module units 4, secondary device possible, connectable more→conductor cross-section duck 0.5 - 25mm², 3 protected poles, nom. (measuring) voltage 400V.
161.93Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
The Legrand DX3 circuit breaker can be connected with either pin or fork terminal rails. Short circuit breaking capacity according to IEC 60947-2 - 16kA. In addition, this Legrand circuit breaker can more→be equipped with DX3 auxiliary contacts. The DX3 circuit breaker cannot be fitted with ground fault elements. Legrand Lexic DX3 circuit breakers are available in different variants.
166.24Buy!
£
Tameson.co.uk
Delivery: in United Kingdom
Report
This easy-to-use FAZ installation circuit breaker features window and elevator terminals at the top and bottom. Thanks to contact position indicators (CPI), you always know the status of the contacts. more→The 3-position DIN-rail clip allows removal from existing busbar. Eaton Moeller FAZ circuit breakers are available in several variants.